Environment - simulationEnvironment: startTime=0 stopTime=10 tolerance=1e-06 numberOfIntervals=50000 stepSize=0.0002 Regular simulation: ./Modelica_4.1.0_Modelica.Electrical.PowerConverters.Examples.ACDC.RectifierCenterTap2Pulse.ThyristorCenterTap2Pulse_RLV_Characteristic -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00356143s reading init.xml | | | | | | 0.000288381s reading info.xml | | | | | | 0.000499397s [ 0.0%] pre-initialization | | | | | | 8.9548e-05s [ 0.0%] initialization | | | | | | 2.685e-06s [ 0.0%] steps | | | | | | 0.104486s [ 10.4%] solver (excl. callbacks) | | | | | | 0.0202206s [ 2.0%] creating output-file | | | | | | 0.417556s [ 41.7%] event-handling | | | | | | 0.010584s [ 1.1%] overhead | | | | | | 0.447927s [ 44.7%] simulation | | | | | | 1.00137s [100.0%] total | | | | | events | | | | | | 2866 state events | | | | | | 1000 time events | | | | | solver: dassl | | | | | | 122893 steps taken | | | | | | 154639 calls of functionODE | | | | | | 36555 evaluations of jacobian | | | | | | 2621 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0621426s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.