Environment - simulationEnvironment: startTime=0 stopTime=4 tolerance=1e-06 numberOfIntervals=4000 stepSize=0.001 Regular simulation: ./HanserModelica_HanserModelica.Electrical.Tables -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00114017s reading init.xml | | | | | | 0.000100639s reading info.xml | | | | | | 9.7002e-05s [ 1.8%] pre-initialization | | | | | | 8.5841e-05s [ 1.6%] initialization | | | | | | 8.22e-07s [ 0.0%] steps | | | | | | 0.000618972s [ 11.4%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000300119s [ 5.5%] event-handling | | | | | | 0.000863075s [ 15.9%] overhead | | | | | | 0.00345823s [ 63.8%] simulation | | | | | | 0.00542406s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 290 steps taken | | | | | | 378 calls of functionODE | | | | | | 79 evaluations of jacobian | | | | | | 13 error test failures | | | | | | 0 convergence test failures | | | | | | 2.2693e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.