Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=6241 stepSize=27.6879 Regular simulation: ./Buildings_latest_Buildings.Fluid.HeatExchangers.CoolingTowers.Validation.MerkelEnergyPlus -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((dat.PFan_Q_flow_nominal >= -0.1 and dat.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= dat.PFan_Q_flow_nominal <= 0.0, has value: 0.00851552" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((tow.dat.PFan_Q_flow_nominal >= -0.1 and tow.dat.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= tow.dat.PFan_Q_flow_nominal <= 0.0, has value: 0.00851552" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/HeatExchangers/CoolingTowers/Data/BaseClasses/BaseCoolingTower.mo:27:3-28:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((tow.per.dat.PFan_Q_flow_nominal >= -0.1 and tow.per.dat.PFan_Q_flow_nominal <= 0.0)) --> "Variable violating min/max constraint: -0.1 <= tow.per.dat.PFan_Q_flow_nominal <= 0.0, has value: 0.00851552" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/HeatExchangers/CoolingTowers/BaseClasses/Merkel.mo:68:3-69:53:writable] | | | | The following assertion has been violated at time 25260.000003 | | | | ((tow.per.FRWat >= 0.0 and tow.per.FRWat <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= tow.per.FRWat <= 1.0, has value: 1.0006" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00788407s reading init.xml | | | | | | 0.000763031s reading info.xml | | | | | | 0.000780293s [ 0.3%] pre-initialization | | | | | | 0.00216901s [ 0.8%] initialization | | | | | | 7.283e-06s [ 0.0%] steps | | | | | | 0.0211274s [ 7.6%] solver (excl. callbacks) | | | | | | 0.0032277s [ 1.2%] creating output-file | | | | | | 0.0437405s [ 15.7%] event-handling | | | | | | 0.0194623s [ 7.0%] overhead | | | | | | 0.187887s [ 67.5%] simulation | | | | | | 0.278402s [100.0%] total | | | | | events | | | | | | 2879 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 42224 steps taken | | | | | | 48932 calls of functionODE | | | | | | 32289 evaluations of jacobian | | | | | | 566 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0530215s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.