Environment - simulationEnvironment: startTime=0 stopTime=100 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.04 Regular simulation: ./Buildings_latest_Buildings.Fluid.FixedResistances.Examples.FlowJunction -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00793857s reading init.xml | | | | | | 0.000868338s reading info.xml | | | | | | 0.000601118s [ 7.6%] pre-initialization | | | | | | 0.000206247s [ 2.6%] initialization | | | | | | 1.533e-06s [ 0.0%] steps | | | | | | 0.000698633s [ 8.8%] solver (excl. callbacks) | | | | | | 0.000940478s [ 11.9%] creating output-file | | | | | | 0.00022754s [ 2.9%] event-handling | | | | | | 0.00109375s [ 13.8%] overhead | | | | | | 0.00414708s [ 52.4%] simulation | | | | | | 0.00791638s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 272 steps taken | | | | | | 418 calls of functionODE | | | | | | 105 evaluations of jacobian | | | | | | 16 error test failures | | | | | | 1 convergence test failures | | | | | | 0.000179617s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.