Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_2 -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro master/Fluid/Machines/CentrifugalPump.mo:48:3-48:45:writable] | | | | The following assertion has been violated at time 99.200000 | | | | ((centrifugalPump.hn >= 0.0)) --> "Variable violating min constraint: 0.0 <= centrifugalPump.hn, has value: -0.0307511" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00509659s reading init.xml | | | | | | 0.000294693s reading info.xml | | | | | | 6.7186e-05s [ 0.1%] pre-initialization | | | | | | 0.000895219s [ 0.8%] initialization | | | | | | 2.8263e-05s [ 0.0%] steps | | | | | | 1.5534e-05s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000259982s [ 0.2%] event-handling | | | | | | 0.0101825s [ 8.8%] overhead | | | | | | 0.10433s [ 90.1%] simulation | | | | | | 0.115779s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 2502 steps taken | | | | | | 2502 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.