Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_12_Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.ConventionalWinter -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zonAHUOpt.sinZonFlo.ports[2].m_flow >= -1e5 and zonAHUOpt.sinZonFlo.ports[2].m_flow <= 0.0)) --> "Variable violating min/max constraint: -1e5 <= zonAHUOpt.sinZonFlo.ports[2].m_flow <= 0.0, has value: 0.0509126" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zonAHUCon.sinZonFlo.ports[2].m_flow >= -1e5 and zonAHUCon.sinZonFlo.ports[2].m_flow <= 0.0)) --> "Variable violating min/max constraint: -1e5 <= zonAHUCon.sinZonFlo.ports[2].m_flow <= 0.0, has value: 0.0509126" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Interfaces/PartialTwoPortTransport.mo:34:3-36:69:writable] | | | | The following assertion has been violated at time 115200.000000 | | | | ((zonAHUOpt.hvac.ideVal.preMasFlo.m_flow >= 0.0 and zonAHUOpt.hvac.ideVal.preMasFlo.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= zonAHUOpt.hvac.ideVal.preMasFlo.m_flow <= 1e5, has value: -2.29589e-41" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 374400.000000 | | | | ((zonAHUOpt.hvac.cooCoi.m1_flow >= 0.0 and zonAHUOpt.hvac.cooCoi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= zonAHUOpt.hvac.cooCoi.m1_flow <= 1e5, has value: -2.29589e-41" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.629671s reading init.xml | | | | | | 0.05097s reading info.xml | | | | | | 0.0154308s [ 0.1%] pre-initialization | | | | | | 0.0717774s [ 0.7%] initialization | | | | | | 0.0012692s [ 0.0%] steps | | | | | | 0.18484s [ 1.7%] solver (excl. callbacks) | | | | | | 0.057147s [ 0.5%] creating output-file | | | | | | 2.0629s [ 19.2%] event-handling | | | | | | 0.0529427s [ 0.5%] overhead | | | | | | 8.27998s [ 77.2%] simulation | | | | | | 10.7263s [100.0%] total | | | | | events | | | | | | 81 state events | | | | | | 8 time events | | | | | solver: dassl | | | | | | 6984 steps taken | | | | | | 9828 calls of functionODE | | | | | | 1506 evaluations of jacobian | | | | | | 394 error test failures | | | | | | 0 convergence test failures | | | | | | 6.13719s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.