Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_11_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariable -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 60825.600000 | | | | ((loa1.loa.coi.SHR >= 0.0 and loa1.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa1.loa.coi.SHR <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((loa.loa.coi.SHR >= 0.0 and loa.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa.loa.coi.SHR <= 1.0, has value: -1.40775e-20" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79280.640000 | | | | ((pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumSpe.eff.yMot, has value: -2.14355e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79280.640000 | | | | ((con.pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.eff.yMot, has value: -3.35457e-21" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 79315.200000 | | | | ((pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumSpe.etaHyd, has value: -2.3012e-30" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 79315.200000 | | | | ((con.pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.etaHyd, has value: -9.66725e-30" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.103675s reading init.xml | | | | | | 0.00801313s reading info.xml | | | | | | 0.00266727s [ 0.8%] pre-initialization | | | | | | 0.00151021s [ 0.4%] initialization | | | | | | 0.000334147s [ 0.1%] steps | | | | | | 0.0180113s [ 5.3%] solver (excl. callbacks) | | | | | | 0.00792711s [ 2.3%] creating output-file | | | | | | 0.00223289s [ 0.7%] event-handling | | | | | | 0.0279284s [ 8.2%] overhead | | | | | | 0.281013s [ 82.3%] simulation | | | | | | 0.341624s [100.0%] total | | | | | events | | | | | | 8 state events | | | | | | 4 time events | | | | | solver: dassl | | | | | | 3179 steps taken | | | | | | 4508 calls of functionODE | | | | | | 385 evaluations of jacobian | | | | | | 154 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0592344s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.