Environment - simulationEnvironment: startTime=-1 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0008 Regular simulation: ./Buildings_11_Buildings.Fluid.FixedResistances.Validation.PressureDropsExplicitLinearized -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00790014s reading init.xml | | | | | | 0.000489829s reading info.xml | | | | | | 0.000326713s [ 5.6%] pre-initialization | | | | | | 0.000204333s [ 3.5%] initialization | | | | | | 1.292e-06s [ 0.0%] steps | | | | | | 9.135e-06s [ 0.2%] solver (excl. callbacks) | | | | | | 0.000590768s [ 10.1%] creating output-file | | | | | | 1.2628e-05s [ 0.2%] event-handling | | | | | | 0.00110422s [ 18.9%] overhead | | | | | | 0.00359565s [ 61.5%] simulation | | | | | | 0.00584474s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 2501 steps taken | | | | | | 2501 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.