startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=1000 stepSize=1 Regular simulation: ./ThermofluidStream_ThermofluidStream.Processes.Tests.ConvectivePipe -abortSlowSimulation -alarm=1200 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00209046s reading init.xml | | | | | | 0.000181431s reading info.xml | | | | | | 0.000177002s [ 2.1%] pre-initialization | | | | | | 0.000153768s [ 1.8%] initialization | | | | | | 1.773e-06s [ 0.0%] steps | | | | | | 0.000416396s [ 4.9%] solver (excl. callbacks) | | | | | | 0.000318821s [ 3.8%] creating output-file | | | | | | 0.000195983s [ 2.3%] event-handling | | | | | | 0.00222067s [ 26.3%] overhead | | | | | | 0.00495474s [ 58.7%] simulation | | | | | | 0.00843915s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 306 steps taken | | | | | | 433 calls of functionODE | | | | | | 77 evaluations of jacobian | | | | | | 10 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000232277s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.