startTime=0 stopTime=4e-06 tolerance=1e-08 numberOfIntervals=1999 stepSize=2.001e-09 Regular simulation: ./ScalableTestSuite_ScalableTestSuite.Electrical.TransmissionLine.ScaledExperiments.TransmissionLineEquations_N_1280 -abortSlowSimulation -alarm=300 -s=ida -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0507199s reading init.xml | | | | | | 0.00486803s reading info.xml | | | | | | 0.000853591s [ 0.0%] pre-initialization | | | | | | 0.00055465s [ 0.0%] initialization | | | | | | 0.00297951s [ 0.0%] steps | | | | | | 5.68043s [ 55.1%] solver (excl. callbacks) | | | | | | 0.0613422s [ 0.6%] creating output-file | | | | | | 0.00103391s [ 0.0%] event-handling | | | | | | 0.00189585s [ 0.0%] overhead | | | | | | 4.55191s [ 44.2%] simulation | | | | | | 10.301s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 33087 steps taken | | | | | | 41245 calls of functionODE | | | | | | 36 evaluations of jacobian | | | | | | 2 error test failures | | | | | | 0 convergence test failures | | | | | | 0.379772s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.