Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_latest_PowerSystems.Examples.AC3ph.Generation.Islanding.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo", uses=false) Using package PowerSystems with version 1.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerSystems.Examples.AC3ph.Generation.Islanding,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="ACpower.p.1.|ACpower.p.2.|ACpower.p.3.|DCpower.p|DCvoltage.v|Time",fileNamePrefix="PowerSystems_latest_PowerSystems.Examples.AC3ph.Generation.Islanding") translateModel(PowerSystems.Examples.AC3ph.Generation.Islanding,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="ACpower.p.1.|ACpower.p.2.|ACpower.p.3.|DCpower.p|DCvoltage.v|Time",fileNamePrefix="PowerSystems_latest_PowerSystems.Examples.AC3ph.Generation.Islanding") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00106/0.00106, allocations: 175.8 kB / 17.4 MB, free: 4.418 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.528/1.528, allocations: 205.4 MB / 223.5 MB, free: 9.02 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009568/0.0009568, allocations: 89.48 kB / 271.9 MB, free: 8.246 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo): time 0.1795/0.1795, allocations: 38.08 MB / 358.3 MB, free: 1.727 MB / 298.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003621/0.0003621, allocations: 16 kB / 425.2 MB, free: 37.35 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3404/0.3407, allocations: 56.32 MB / 481.6 MB, free: 9.578 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.1974/0.5382, allocations: 137.6 MB / 0.6047 GB, free: 12.55 MB / 442.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000359/0.5386, allocations: 107.8 kB / 0.6048 GB, free: 12.45 MB / 442.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/AC3ph/Machines.mo:2240:3-2240:48:writable] Error: Could not evaluate structural parameter (or constant): n_d which gives dimensions of array: L_rd[n_d]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.AC3ph.Generation.Islanding Notification: Performance of FrontEnd: time 0.1171/0.6558, allocations: 42.17 MB / 0.646 GB, free: 1.793 MB / 474.7 MB