startTime=0 stopTime=8 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0032 Regular simulation: ./ModelicaTest_3.2.3_ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpDCMotor -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00831466s reading init.xml | | | | | | 0.000727725s reading info.xml | | | | | | 0.000284023s [ 0.0%] pre-initialization | | | | | | 0.00330752s [ 0.2%] initialization | | | | | | 0.000300414s [ 0.0%] steps | | | | | | 0.00311436s [ 0.2%] solver (excl. callbacks) | | | | | | 0.00486556s [ 0.3%] creating output-file | | | | | | 0.970999s [ 52.3%] event-handling | | | | | | 0.0192504s [ 1.0%] overhead | | | | | | 0.852858s [ 46.0%] simulation | | | | | | 1.85498s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 397 steps taken | | | | | | 499 calls of functionODE | | | | | | 83 evaluations of jacobian | | | | | | 9 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0197278s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.