Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr IBPSA_master_IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package IBPSA with version 3.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 3.0.0-master/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IBPSA_master_IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002594/0.002598, allocations: 354.5 kB / 16.58 MB, free: 5.566 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 3.0.0-master/package.mo): time 1.409/1.409, allocations: 165.8 MB / 183.1 MB, free: 5.434 MB / 138.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 3.807/3.807, allocations: 410.7 MB / 0.6001 GB, free: 15.07 MB / 298.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001785/0.001785, allocations: 198.4 kB / 0.6668 GB, free: 6.895 MB / 298.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0004853/0.0004855, allocations: 12 kB / 0.7429 GB, free: 8.883 MB / 378.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4147/0.4152, allocations: 67.42 MB / 0.8088 GB, free: 28.76 MB / 378.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.1682/0.5835, allocations: 99.12 MB / 0.9056 GB, free: 9.512 MB / 458.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004211/0.584, allocations: 115.9 kB / 0.9057 GB, free: 9.398 MB / 458.7 MB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 3.0.0-master/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/LoadAggregation/Validation/ShiftAggregationCells.mo:15:5-20:21:writable] Error: Type mismatch for named argument in IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.shiftAggregationCells(rCel={1, 1, 1, 2, 2}). The argument has type: Integer[5] expected type: Real[i] Error: Error occurred while flattening model IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells Notification: Performance of FrontEnd: time 0.00295/0.5869, allocations: 0.8679 MB / 0.9065 GB, free: 8.531 MB / 458.7 MB