Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_master_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 4.953/4.953, allocations: 0.5623 GB / 0.5775 GB, free: 3.309 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002513/0.002512, allocations: 356.8 kB / 0.6446 GB, free: 185.6 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 4.272/4.272, allocations: 410.7 MB / 1.113 GB, free: 5.898 MB / 0.6042 GB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001892/0.001891, allocations: 187.5 kB / 1.226 GB, free: 6.145 MB / 0.7136 GB Notification: Performance of FrontEnd - loaded program: time 0.0007615/0.000762, allocations: 16 kB / 1.349 GB, free: 8.273 MB / 0.8386 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.76/0.7608, allocations: 115.3 MB / 1.461 GB, free: 284.3 MB / 0.8542 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.119/7.88, allocations: 2.112 GB / 3.573 GB, free: 265.9 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003458/7.88, allocations: 101.9 kB / 3.573 GB, free: 265.9 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear Notification: Performance of FrontEnd: time 0.5322/8.413, allocations: 156.5 MB / 3.726 GB, free: 145.1 MB / 0.948 GB