Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.ThermalZones.EnergyPlus.Validation.Schedule.EquipmentScheduleOutputVariable.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Validation.Schedule.EquipmentScheduleOutputVariable,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_master_Buildings.ThermalZones.EnergyPlus.Validation.Schedule.EquipmentScheduleOutputVariable") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 5.063/5.063, allocations: 0.5623 GB / 0.5775 GB, free: 3.34 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002589/0.002588, allocations: 354.6 kB / 0.6446 GB, free: 185.7 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 4.207/4.207, allocations: 410.7 MB / 1.113 GB, free: 6.008 MB / 0.6042 GB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001832/0.001832, allocations: 183.4 kB / 1.226 GB, free: 6.172 MB / 0.7136 GB Notification: Performance of FrontEnd - loaded program: time 0.0005188/0.000519, allocations: 12 kB / 1.349 GB, free: 8.309 MB / 0.8386 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7829/0.7834, allocations: 115.3 MB / 1.461 GB, free: 284.4 MB / 0.8542 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.858/7.641, allocations: 2.116 GB / 3.577 GB, free: 264.5 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003545/7.642, allocations: 105.5 kB / 3.577 GB, free: 264.5 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.Schedule.EquipmentScheduleOutputVariable Notification: Performance of FrontEnd: time 0.5227/8.165, allocations: 156.6 MB / 3.73 GB, free: 140.8 MB / 0.948 GB