Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_master_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 5.433/5.433, allocations: 0.5623 GB / 0.5775 GB, free: 3.367 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002509/0.002509, allocations: 366.8 kB / 0.6446 GB, free: 185.6 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 4.273/4.273, allocations: 410.7 MB / 1.113 GB, free: 6.008 MB / 0.6042 GB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001837/0.001837, allocations: 179.2 kB / 1.226 GB, free: 6.18 MB / 0.7136 GB Notification: Performance of FrontEnd - loaded program: time 0.0005375/0.0005377, allocations: 15.98 kB / 1.349 GB, free: 8.316 MB / 0.8386 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7419/0.7425, allocations: 115.3 MB / 1.461 GB, free: 284.4 MB / 0.8542 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.949/7.691, allocations: 2.113 GB / 3.574 GB, free: 265.8 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000375/7.692, allocations: 104.7 kB / 3.574 GB, free: 265.8 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables Notification: Performance of FrontEnd: time 0.5164/8.208, allocations: 156.6 MB / 3.727 GB, free: 143.9 MB / 0.948 GB