Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOneOutputVariable.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOneOutputVariable,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_master_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOneOutputVariable") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 5.033/5.033, allocations: 0.5623 GB / 0.5775 GB, free: 3.34 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002533/0.002532, allocations: 347.8 kB / 0.6446 GB, free: 185.7 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 4.345/4.345, allocations: 410.7 MB / 1.113 GB, free: 6 MB / 0.6042 GB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001901/0.001901, allocations: 190.4 kB / 1.226 GB, free: 6.145 MB / 0.7136 GB Notification: Performance of FrontEnd - loaded program: time 0.000513/0.0005131, allocations: 19.98 kB / 1.349 GB, free: 8.277 MB / 0.8386 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7483/0.7489, allocations: 115.3 MB / 1.461 GB, free: 284.3 MB / 0.8542 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.762/7.511, allocations: 2.113 GB / 3.574 GB, free: 265.2 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003512/7.511, allocations: 108.8 kB / 3.574 GB, free: 265.2 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneZoneOneOutputVariable Notification: Performance of FrontEnd: time 0.5288/8.04, allocations: 156.5 MB / 3.727 GB, free: 143.8 MB / 0.948 GB