Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_master_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 5.105/5.105, allocations: 0.5623 GB / 0.5775 GB, free: 3.387 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00245/0.00245, allocations: 358.2 kB / 0.6446 GB, free: 185.7 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 4.393/4.393, allocations: 410.7 MB / 1.113 GB, free: 5.941 MB / 0.6042 GB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001908/0.001907, allocations: 194.2 kB / 1.226 GB, free: 6.148 MB / 0.7136 GB Notification: Performance of FrontEnd - loaded program: time 0.0005293/0.0005295, allocations: 16 kB / 1.349 GB, free: 8.285 MB / 0.8386 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7535/0.7541, allocations: 115.3 MB / 1.461 GB, free: 284.4 MB / 0.8542 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.71/7.465, allocations: 2.132 GB / 3.593 GB, free: 255.4 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004009/7.465, allocations: 113.9 kB / 3.594 GB, free: 255.4 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring Notification: Performance of FrontEnd: time 9.145/16.61, allocations: 1.629 GB / 5.223 GB, free: 95.33 MB / 0.9948 GB