Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_master_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 4.69/4.69, allocations: 0.5623 GB / 0.5775 GB, free: 66.93 MB / 330.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002657/0.002657, allocations: 361.5 kB / 0.6446 GB, free: 21.51 MB / 330.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 4.329/4.329, allocations: 410.7 MB / 1.113 GB, free: 109.7 MB / 0.5573 GB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001856/0.001856, allocations: 177.3 kB / 1.226 GB, free: 9.551 MB / 0.573 GB Notification: Performance of FrontEnd - loaded program: time 0.0007531/0.0007533, allocations: 12 kB / 1.349 GB, free: 84.64 MB / 0.573 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2566/0.2574, allocations: 115.3 MB / 1.461 GB, free: 1.281 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.957/8.215, allocations: 2.246 GB / 3.707 GB, free: 220.9 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000533/8.215, allocations: 127.6 kB / 3.707 GB, free: 220.8 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:199:3-207:69:writable] Error: Variable staRes: In modifier (minT(Min = 254.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650 Notification: Performance of FrontEnd: time 1.493/9.708, allocations: 231 MB / 3.933 GB, free: 213.4 MB / 0.948 GB