Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_master_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 4.95/4.95, allocations: 0.5623 GB / 0.5776 GB, free: 3.336 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002508/0.002508, allocations: 356.2 kB / 0.6446 GB, free: 185.6 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 4.373/4.373, allocations: 410.7 MB / 1.113 GB, free: 5.91 MB / 0.6042 GB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001876/0.001876, allocations: 186.9 kB / 1.226 GB, free: 6.078 MB / 0.7136 GB Notification: Performance of FrontEnd - loaded program: time 0.0005602/0.0005604, allocations: 16 kB / 1.349 GB, free: 8.207 MB / 0.8386 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7753/0.7759, allocations: 115.3 MB / 1.461 GB, free: 284.3 MB / 0.8542 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.834/7.61, allocations: 2.246 GB / 3.707 GB, free: 150.8 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005332/7.611, allocations: 120.8 kB / 3.707 GB, free: 150.7 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:199:3-207:69:writable] Error: Variable staRes: In modifier (minT(Min = 254.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610 Notification: Performance of FrontEnd: time 1.485/9.096, allocations: 231 MB / 3.933 GB, free: 241.8 MB / 0.948 GB