Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_master_Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 5.064/5.064, allocations: 0.5623 GB / 0.5775 GB, free: 3.352 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002486/0.002485, allocations: 356.1 kB / 0.6446 GB, free: 185.7 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 4.318/4.318, allocations: 410.7 MB / 1.113 GB, free: 147.9 MB / 0.5886 GB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001845/0.001845, allocations: 170.7 kB / 1.226 GB, free: 36.02 MB / 0.5886 GB Notification: Performance of FrontEnd - loaded program: time 0.0004791/0.0004792, allocations: 12 kB / 1.349 GB, free: 121.8 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2115/0.212, allocations: 115.3 MB / 1.461 GB, free: 6.641 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.765/6.977, allocations: 2.091 GB / 3.552 GB, free: 130 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003893/6.977, allocations: 106.6 kB / 3.552 GB, free: 129.9 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/ThermalZones/Detailed/BaseClasses/Examples/MixedAirHeatMassBalance.mo:16:11-16:36:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.BaseClasses.Examples.MixedAirHeatMassBalance Notification: Performance of FrontEnd: time 1.328/8.305, allocations: 173.1 MB / 3.721 GB, free: 281.1 MB / 0.948 GB