Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_master_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 9.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_master_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 4.92/4.92, allocations: 0.5623 GB / 0.5775 GB, free: 3.355 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002501/0.0025, allocations: 360.2 kB / 0.6446 GB, free: 185.6 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 4.319/4.319, allocations: 410.7 MB / 1.113 GB, free: 5.988 MB / 0.6042 GB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001804/0.001804, allocations: 170.6 kB / 1.226 GB, free: 6.172 MB / 0.7136 GB Notification: Performance of FrontEnd - loaded program: time 0.0005091/0.0005095, allocations: 15.98 kB / 1.349 GB, free: 8.305 MB / 0.8386 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7396/0.7402, allocations: 115.3 MB / 1.461 GB, free: 284.4 MB / 0.8542 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.708/7.448, allocations: 2.106 GB / 3.567 GB, free: 266.4 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003497/7.449, allocations: 110.9 kB / 3.567 GB, free: 266.4 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented Notification: Performance of FrontEnd: time 0.05125/7.5, allocations: 12.39 MB / 3.579 GB, free: 265.2 MB / 0.948 GB