Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.ThermalZones.Detailed.Constructions.Examples.ExteriorWallTwoWindows.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Constructions.Examples.ExteriorWallTwoWindows,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.ThermalZones.Detailed.Constructions.Examples.ExteriorWallTwoWindows") translateModel(Buildings.ThermalZones.Detailed.Constructions.Examples.ExteriorWallTwoWindows,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.ThermalZones.Detailed.Constructions.Examples.ExteriorWallTwoWindows") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.262/1.262, allocations: 252 MB / 267.9 MB, free: 10.93 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009716/0.0009716, allocations: 182.8 kB / 327.6 MB, free: 2.172 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.394/1.394, allocations: 205.4 MB / 0.5785 GB, free: 20.19 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007312/0.0007314, allocations: 88.53 kB / 0.6831 GB, free: 12.86 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0003309/0.000331, allocations: 11.19 kB / 0.7974 GB, free: 135.1 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1516/0.152, allocations: 106.3 MB / 0.9012 GB, free: 63.76 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.073/4.225, allocations: 2.248 GB / 3.149 GB, free: 317.4 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002718/4.225, allocations: 94.72 kB / 3.15 GB, free: 317.4 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/ThermalZones/Detailed/Constructions/Examples/ExteriorWallTwoWindows.mo:62:5-62:18:writable] Error: Type mismatch in binding A = {30.0, 30.0}, expected subtype of Real, got type Real[2]. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Constructions.Examples.ExteriorWallTwoWindows Notification: Performance of FrontEnd: time 0.4264/4.651, allocations: 194.1 MB / 3.339 GB, free: 138 MB / 0.8855 GB