startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./Buildings_maint.7.0.x_Buildings.Fluid.Movers.Examples.MoverStages -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pump_m_flow.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0199563s reading init.xml | | | | | | 0.00205005s reading info.xml | | | | | | 0.000135514s [ 0.2%] pre-initialization | | | | | | 0.000533511s [ 0.7%] initialization | | | | | | 8.897e-06s [ 0.0%] steps | | | | | | 5.3634e-05s [ 0.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00241074s [ 3.2%] event-handling | | | | | | 0.0174728s [ 23.2%] overhead | | | | | | 0.0548342s [ 72.7%] simulation | | | | | | 0.0754493s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 9505 steps taken | | | | | | 9505 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.