Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: translateModel(Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL") translateModel(Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.251/1.251, allocations: 252 MB / 267.9 MB, free: 10.93 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009303/0.0009303, allocations: 182 kB / 327.6 MB, free: 2.156 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.387/1.387, allocations: 205.4 MB / 0.5785 GB, free: 20.2 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007448/0.0007447, allocations: 89.98 kB / 0.6831 GB, free: 12.84 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.000354/0.000354, allocations: 16 kB / 0.7974 GB, free: 135.1 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1735/0.1739, allocations: 106.3 MB / 0.9012 GB, free: 63.7 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.7285/0.9025, allocations: 410.6 MB / 1.302 GB, free: 5.293 MB / 0.8073 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002773/0.9028, allocations: 92.86 kB / 1.302 GB, free: 5.246 MB / 0.8073 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/HeatPumps/Examples/Carnot_y.mo:20:3-34:67:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_y$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL Notification: Performance of FrontEnd: time 0.1353/1.038, allocations: 72.35 MB / 1.373 GB, free: 9.016 MB / 0.8698 GB