Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel") translateModel(Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.331/1.331, allocations: 252 MB / 267.9 MB, free: 10.92 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009266/0.0009265, allocations: 183 kB / 327.6 MB, free: 2.168 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.44/1.44, allocations: 205.4 MB / 0.5785 GB, free: 20.17 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007661/0.0007661, allocations: 94.34 kB / 0.6831 GB, free: 12.83 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0003558/0.000356, allocations: 11.75 kB / 0.7974 GB, free: 135.1 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1866/0.1869, allocations: 106.3 MB / 0.9012 GB, free: 63.68 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.28/4.467, allocations: 2.525 GB / 3.427 GB, free: 21.94 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002783/4.468, allocations: 117.6 kB / 3.427 GB, free: 21.83 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/HeatExchangers/CoolingTowers/Examples/BaseClasses/PartialStaticTwoPortCoolingTower.mo:11:3-20:71:writable] Error: component tow contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.HeatExchangers.CoolingTowers.Examples.Merkel Notification: Performance of FrontEnd: time 2.446/6.914, allocations: 0.7277 GB / 4.155 GB, free: 118.7 MB / 0.8855 GB