Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: translateModel(Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop") translateModel(Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.341/1.341, allocations: 252 MB / 267.9 MB, free: 10.93 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009592/0.0009593, allocations: 186.6 kB / 327.6 MB, free: 2.156 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.622/1.622, allocations: 205.4 MB / 0.5785 GB, free: 20.2 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008105/0.0008106, allocations: 94.27 kB / 0.6831 GB, free: 12.83 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004661/0.0004661, allocations: 12.94 kB / 0.7974 GB, free: 135.2 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1965/0.1969, allocations: 106.3 MB / 0.9012 GB, free: 63.68 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.8866/1.084, allocations: 451.8 MB / 1.342 GB, free: 12.34 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002603/1.084, allocations: 98.77 kB / 1.342 GB, free: 12.29 MB / 0.8542 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Boilers/Examples/BoilerPolynomialClosedLoop.mo:11:3-21:72:writable] Error: component boi contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop Notification: Performance of FrontEnd: time 0.8456/1.929, allocations: 223.7 MB / 1.561 GB, free: 195.9 MB / 0.8855 GB