Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Examples.ChillerPlant.DataCenterRenewables.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: translateModel(Buildings.Examples.ChillerPlant.DataCenterRenewables,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Examples.ChillerPlant.DataCenterRenewables") translateModel(Buildings.Examples.ChillerPlant.DataCenterRenewables,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Examples.ChillerPlant.DataCenterRenewables") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.289/1.289, allocations: 252 MB / 267.9 MB, free: 10.91 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009014/0.0009014, allocations: 178.7 kB / 327.5 MB, free: 2.141 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.626/1.626, allocations: 205.4 MB / 0.5785 GB, free: 20.18 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007835/0.0007837, allocations: 86.36 kB / 0.6831 GB, free: 12.81 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0003815/0.0003816, allocations: 16.05 kB / 0.7974 GB, free: 135.1 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1935/0.1939, allocations: 106.3 MB / 0.9012 GB, free: 63.68 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.378/5.572, allocations: 2.603 GB / 3.505 GB, free: 288.1 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002248/5.572, allocations: 97.44 kB / 3.505 GB, free: 288.1 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:85:3-88:73:writable] Notification: Moving binding to initial equation section and setting fixed attribute of dataCenterContinuousTimeControl.roo.rooVol.state_default.p to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:85:3-88:73:writable] Notification: Moving binding to initial equation section and setting fixed attribute of dataCenterContinuousTimeControl.roo.rooVol.state_default.T to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:85:3-88:73:writable] Notification: Moving binding to initial equation section and setting fixed attribute of dataCenterContinuousTimeControl.roo.rooVol.state_default.X[1] to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:85:3-88:73:writable] Notification: Moving binding to initial equation section and setting fixed attribute of dataCenterContinuousTimeControl.roo.rooVol.state_default.X[2] to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:92:3-95:62:writable] Notification: Moving binding to initial equation section and setting fixed attribute of dataCenterContinuousTimeControl.roo.rooVol.state_start.p to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:92:3-95:62:writable] Notification: Moving binding to initial equation section and setting fixed attribute of dataCenterContinuousTimeControl.roo.rooVol.state_start.T to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:92:3-95:62:writable] Notification: Moving binding to initial equation section and setting fixed attribute of dataCenterContinuousTimeControl.roo.rooVol.state_start.X[1] to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:92:3-95:62:writable] Notification: Moving binding to initial equation section and setting fixed attribute of dataCenterContinuousTimeControl.roo.rooVol.state_start.X[2] to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Interfaces/ConservationEquation.mo:140:3-143:73:writable] Notification: Moving binding to initial equation section and setting fixed attribute of dataCenterContinuousTimeControl.roo.rooVol.dynBal.state_default.p to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Interfaces/ConservationEquation.mo:140:3-143:73:writable] Notification: Moving binding to initial equation section and setting fixed attribute of dataCenterContinuousTimeControl.roo.rooVol.dynBal.state_default.T to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Interfaces/ConservationEquation.mo:140:3-143:73:writable] Notification: Moving binding to initial equation section and setting fixed attribute of dataCenterContinuousTimeControl.roo.rooVol.dynBal.state_default.X[1] to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Interfaces/ConservationEquation.mo:140:3-143:73:writable] Notification: Moving binding to initial equation section and setting fixed attribute of dataCenterContinuousTimeControl.roo.rooVol.dynBal.state_default.X[2] to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Examples.ChillerPlant.DataCenterRenewables Notification: Performance of FrontEnd: time 16.31/21.89, allocations: 5.012 GB / 8.517 GB, free: 58.33 MB / 1.089 GB