Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable") translateModel(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 1.794/1.794, allocations: 297.8 MB / 313.7 MB, free: 172 kB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001526/0.001526, allocations: 176.5 kB / 384.6 MB, free: 10.9 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.613/1.613, allocations: 223.2 MB / 0.6626 GB, free: 4.363 MB / 490.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001076/0.001076, allocations: 95.41 kB / 0.7808 GB, free: 50.32 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0005138/0.0005139, allocations: 14.91 kB / 0.9088 GB, free: 2.918 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.9196/0.9202, allocations: 120.3 MB / 1.026 GB, free: 55.87 MB / 0.7292 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.991/5.912, allocations: 1.95 GB / 2.976 GB, free: 272.5 MB / 0.9792 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003098/5.912, allocations: 104.2 kB / 2.976 GB, free: 272.5 MB / 0.9792 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-127:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable Notification: Performance of FrontEnd: time 0.3643/6.276, allocations: 187.1 MB / 3.159 GB, free: 95.5 MB / 0.9792 GB