Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir") translateModel(Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 1.726/1.726, allocations: 297.8 MB / 313.7 MB, free: 124 kB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001064/0.001064, allocations: 180.3 kB / 384.6 MB, free: 10.86 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.574/1.574, allocations: 223.2 MB / 0.6626 GB, free: 4.379 MB / 490.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009029/0.0009031, allocations: 99.78 kB / 0.7808 GB, free: 43.59 MB / 0.5417 GB Notification: Performance of FrontEnd - loaded program: time 0.0004702/0.0004704, allocations: 12 kB / 0.9088 GB, free: 0.7109 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.822/0.8224, allocations: 120.3 MB / 1.026 GB, free: 56.36 MB / 0.698 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.742/6.565, allocations: 2.059 GB / 3.085 GB, free: 115.4 MB / 0.9792 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003296/6.565, allocations: 104 kB / 3.085 GB, free: 115.3 MB / 0.9792 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir Notification: Performance of FrontEnd: time 1.478/8.043, allocations: 294.2 MB / 3.372 GB, free: 197.3 MB / 0.9792 GB