Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.Detailed.BaseClasses.Examples.RadiationTemperature.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.BaseClasses.Examples.RadiationTemperature,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.Detailed.BaseClasses.Examples.RadiationTemperature") translateModel(Buildings.ThermalZones.Detailed.BaseClasses.Examples.RadiationTemperature,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.Detailed.BaseClasses.Examples.RadiationTemperature") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 1.792/1.792, allocations: 297.8 MB / 313.7 MB, free: 144 kB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001647/0.001647, allocations: 179.4 kB / 384.6 MB, free: 10.87 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.722/1.722, allocations: 223.2 MB / 0.6626 GB, free: 4.324 MB / 490.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001052/0.001052, allocations: 97.34 kB / 0.7808 GB, free: 50.34 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.000463/0.000463, allocations: 16.48 kB / 0.9088 GB, free: 2.891 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.9259/0.9264, allocations: 120.3 MB / 1.026 GB, free: 55.82 MB / 0.7292 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.2555/1.182, allocations: 161.9 MB / 1.184 GB, free: 15.87 MB / 0.7605 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004024/1.182, allocations: 101.7 kB / 1.185 GB, free: 15.77 MB / 0.7605 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/ThermalZones/Detailed/BaseClasses/Examples/RadiationTemperature.mo:20:11-20:36:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.BaseClasses.Examples.RadiationTemperature Notification: Performance of FrontEnd: time 0.1506/1.333, allocations: 54.32 MB / 1.238 GB, free: 9.785 MB / 0.8073 GB