Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow") translateModel(Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 1.659/1.659, allocations: 297.8 MB / 313.7 MB, free: 136 kB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009542/0.0009544, allocations: 183 kB / 384.6 MB, free: 10.87 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.475/1.475, allocations: 223.2 MB / 0.6626 GB, free: 4.277 MB / 490.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009602/0.0009601, allocations: 94.88 kB / 0.7808 GB, free: 50.32 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004275/0.0004276, allocations: 14.22 kB / 0.9088 GB, free: 2.875 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7151/0.7155, allocations: 120.3 MB / 1.026 GB, free: 55.79 MB / 0.7292 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.177/5.893, allocations: 2.292 GB / 3.318 GB, free: 305.3 MB / 0.9948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004258/5.893, allocations: 97.66 kB / 3.318 GB, free: 305.3 MB / 0.9948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/Utilities/Psychrometrics/X_pTphi.mo:37:3-40:14:writable] Error: Illegal subscript i_w for dimensions 2 in component X[i_w]. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/Utilities/Psychrometrics/X_pTphi.mo:37:3-40:14:writable] Error: Variable X[i_w] not found in scope Buildings.Utilities.Psychrometrics.X_pTphi$x_pTphi. Error: Error occurred while flattening model Buildings.Fluid.HeatExchangers.Examples.WetCoilEffectivenessNTUMassFlow Notification: Performance of FrontEnd: time 0.1116/6.005, allocations: 52.41 MB / 3.369 GB, free: 294.6 MB / 0.9948 GB