Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.Guideline36Winter.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo) Running command: translateModel(Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.Guideline36Winter,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_latest_Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.Guideline36Winter") translateModel(Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.Guideline36Winter,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_latest_Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.Guideline36Winter") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/package.mo): time 1.63/1.63, allocations: 297.8 MB / 313.7 MB, free: 180 kB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009203/0.0009204, allocations: 180.5 kB / 384.6 MB, free: 10.89 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.262/1.262, allocations: 223.2 MB / 0.6626 GB, free: 4.359 MB / 490.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0007267/0.0007267, allocations: 94.95 kB / 0.7808 GB, free: 50.36 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004287/0.0004288, allocations: 16 kB / 0.9088 GB, free: 2.883 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6138/0.6143, allocations: 120.3 MB / 1.026 GB, free: 55.86 MB / 0.7292 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.367/4.981, allocations: 2.42 GB / 3.446 GB, free: 218.1 MB / 0.9948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002861/4.981, allocations: 119.7 kB / 3.446 GB, free: 218.1 MB / 0.9948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/Utilities/Psychrometrics/X_pTphi.mo:37:3-40:14:writable] Error: Illegal subscript i_w for dimensions 2 in component X[i_w]. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.0.0-master/Utilities/Psychrometrics/X_pTphi.mo:37:3-40:14:writable] Error: Variable X[i_w] not found in scope Buildings.Utilities.Psychrometrics.X_pTphi. Error: Error occurred while flattening model Buildings.Air.Systems.SingleZone.VAV.Examples.OptimalStart.Guideline36Winter Notification: Performance of FrontEnd: time 1.099/6.08, allocations: 387.6 MB / 3.825 GB, free: 72.8 MB / 0.9948 GB