Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter") translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.492/2.492, allocations: 287.5 MB / 303.2 MB, free: 8.371 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001352/0.001352, allocations: 191.1 kB / 371.8 MB, free: 10.84 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.016/2.016, allocations: 205.4 MB / 0.6305 GB, free: 10.56 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009747/0.0009747, allocations: 97.09 kB / 0.7438 GB, free: 6.555 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0006272/0.0006274, allocations: 11.19 kB / 0.8667 GB, free: 141 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2112/0.2119, allocations: 115.3 MB / 0.9793 GB, free: 28.22 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.422/6.634, allocations: 2.132 GB / 3.111 GB, free: 163.3 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003055/6.634, allocations: 107.9 kB / 3.112 GB, free: 163.2 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingWinter Notification: Performance of FrontEnd: time 7.955/14.59, allocations: 1.63 GB / 4.742 GB, free: 6.949 MB / 0.9948 GB