Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlySurfaceBoundary.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlySurfaceBoundary,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlySurfaceBoundary") translateModel(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlySurfaceBoundary,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlySurfaceBoundary") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.53/2.53, allocations: 287.5 MB / 303.2 MB, free: 8.238 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001361/0.00136, allocations: 172.5 kB / 371.8 MB, free: 10.83 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.045/2.045, allocations: 205.4 MB / 0.6305 GB, free: 10.56 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009873/0.0009873, allocations: 83.69 kB / 0.7438 GB, free: 6.559 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004693/0.0004696, allocations: 15.69 kB / 0.8667 GB, free: 140.7 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2165/0.217, allocations: 115.3 MB / 0.9793 GB, free: 28.2 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.595/6.812, allocations: 2.214 GB / 3.193 GB, free: 90.05 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003446/6.813, allocations: 103.9 kB / 3.193 GB, free: 89.95 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:249:11-249:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlySurfaceBoundary Notification: Performance of FrontEnd: time 1.419/8.231, allocations: 206.8 MB / 3.395 GB, free: 244.2 MB / 0.948 GB