Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL") translateModel(Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.502/2.502, allocations: 287.5 MB / 303.2 MB, free: 8.285 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001291/0.00129, allocations: 188.7 kB / 371.8 MB, free: 10.75 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.005/2.005, allocations: 205.4 MB / 0.6305 GB, free: 10.53 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009012/0.000901, allocations: 85.11 kB / 0.7438 GB, free: 6.527 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0006249/0.0006252, allocations: 10.84 kB / 0.8667 GB, free: 141.1 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.225/0.2257, allocations: 115.3 MB / 0.9793 GB, free: 28.2 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.276/1.502, allocations: 418.1 MB / 1.388 GB, free: 12.31 MB / 0.9167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003535/1.502, allocations: 96.77 kB / 1.388 GB, free: 12.26 MB / 0.9167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Fluid/HeatPumps/Examples/Carnot_y.mo:20:3-34:67:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_y$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_y_etaPL Notification: Performance of FrontEnd: time 0.8716/2.374, allocations: 74.36 MB / 1.46 GB, free: 318.1 MB / 0.9323 GB