Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature") translateModel(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.521/2.521, allocations: 287.5 MB / 303.2 MB, free: 8.281 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001358/0.001357, allocations: 185.6 kB / 371.8 MB, free: 10.84 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.028/2.028, allocations: 205.4 MB / 0.6305 GB, free: 10.59 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009238/0.0009237, allocations: 92.73 kB / 0.7438 GB, free: 6.574 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0006359/0.000636, allocations: 12.28 kB / 0.8667 GB, free: 140.4 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2143/0.215, allocations: 115.3 MB / 0.9793 GB, free: 28.22 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.284/1.499, allocations: 422.5 MB / 1.392 GB, free: 7.949 MB / 0.9167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000327/1.499, allocations: 99.83 kB / 1.392 GB, free: 7.898 MB / 0.9167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature Notification: Performance of FrontEnd: time 0.9229/2.422, allocations: 84.65 MB / 1.475 GB, free: 310.9 MB / 0.9323 GB