Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary") translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.502/2.502, allocations: 287.5 MB / 303.2 MB, free: 8.289 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001393/0.001393, allocations: 178.3 kB / 371.8 MB, free: 10.82 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.081/2.081, allocations: 205.4 MB / 0.6305 GB, free: 10.53 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001015/0.001014, allocations: 86.33 kB / 0.7438 GB, free: 6.531 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0005016/0.0005017, allocations: 13.06 kB / 0.8667 GB, free: 140.9 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2237/0.2242, allocations: 115.3 MB / 0.9793 GB, free: 28.21 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 2.127/2.351, allocations: 0.5102 GB / 1.489 GB, free: 332.1 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003594/2.352, allocations: 119.4 kB / 1.49 GB, free: 332.1 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Fluid/BaseClasses/PartialResistance.mo:31:3-32:85:writable] Notification: Moving binding to initial equation section and setting fixed attribute of intWSEPriSec1.chiPar.val2[1].sta_default.p to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Fluid/BaseClasses/PartialResistance.mo:31:3-32:85:writable] Notification: Moving binding to initial equation section and setting fixed attribute of intWSEPriSec1.chiPar.val2[1].sta_default.T to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Fluid/BaseClasses/PartialResistance.mo:31:3-32:85:writable] Notification: Moving binding to initial equation section and setting fixed attribute of intWSEPriSec1.chiPar.val1[1].sta_default.p to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Fluid/BaseClasses/PartialResistance.mo:31:3-32:85:writable] Notification: Moving binding to initial equation section and setting fixed attribute of intWSEPriSec1.chiPar.val1[1].sta_default.T to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Applications/DataCenters/ChillerCooled/Equipment/IntegratedPrimarySecondary.mo:116:11-116:21:writable] Error: Type mismatch in binding pressure = Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure({0, 0}, {0, 0}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[2] V_flow; Real(min = 0.0, displayUnit = "Pa", quantity = "Pressure", unit = "Pa")[2] dp; end Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure Integer[2] V_flow; Integer[2] dp; end Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary Notification: Performance of FrontEnd: time 17.43/19.78, allocations: 3.404 GB / 4.894 GB, free: 9.477 MB / 1.089 GB