Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC,tolerance=1e-07,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC") translateModel(Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC,tolerance=1e-07,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.116/2.116, allocations: 251.1 MB / 266.7 MB, free: 11.64 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001362/0.001362, allocations: 181 kB / 326.2 MB, free: 2.879 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.397/2.397, allocations: 205.4 MB / 0.5772 GB, free: 20.76 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009835/0.0009829, allocations: 95.92 kB / 0.6817 GB, free: 13.63 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004781/0.0004781, allocations: 20.06 kB / 0.7957 GB, free: 135.6 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2271/0.2276, allocations: 106.3 MB / 0.8995 GB, free: 65.55 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 8.317/8.545, allocations: 2.566 GB / 3.465 GB, free: 214.5 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003355/8.545, allocations: 120.6 kB / 3.466 GB, free: 214.5 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$fluPor$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$fluPor$backward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$fluPor$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$fluPor$backward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$con$bacPro_internal is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$con$outlet$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$con$outlet$backward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$con$bacPro_internal is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$con$outlet$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$hvacAda$con$outlet$backward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$fluPor$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$fluPor$backward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$fluPor$forward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/MassFractionConnector.mo:2:1-41:11:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.MassFractionConnector is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/Interfaces/FluidProperties.mo:2:1-72:20:writable] Warning: Connector .Buildings.Fluid.FMI.Interfaces.FluidProperties$hvaCon$fluPor$backward is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/FMI/ExportContainers/Examples/FMUs/HVACZone.mo:182:3-185:27:writable] Error: Incompatible components in connect statement: connect(souWat.ports[1], cooCoi.port_a1) - souWat.ports[1] has components {C_outflow, Xi_outflow, h_outflow, m_flow, p} - cooCoi.port_a1 has components {C_outflow, Xi_outflow, h_outflow, m_flow, p} Error: Error occurred while flattening model Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC Notification: Performance of FrontEnd: time 74.68/83.23, allocations: 13.17 GB / 16.64 GB, free: 57.28 MB / 1.151 GB