Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw") translateModel(Buildings.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.131/2.131, allocations: 251.1 MB / 266.7 MB, free: 11.57 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001323/0.001323, allocations: 178.2 kB / 326.2 MB, free: 2.852 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.358/2.358, allocations: 205.4 MB / 0.5772 GB, free: 20.82 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009699/0.0009698, allocations: 106 kB / 0.6817 GB, free: 13.63 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0006383/0.0006386, allocations: 11.91 kB / 0.7957 GB, free: 135.6 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2311/0.2317, allocations: 106.3 MB / 0.8995 GB, free: 65.55 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.267/1.498, allocations: 416.1 MB / 1.306 GB, free: 3.258 MB / 0.8073 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003253/1.499, allocations: 103.6 kB / 1.306 GB, free: 3.203 MB / 0.8073 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Chillers/Validation/Carnot_TEva_2ndLaw.mo:81:5-96:72:writable] Error: Variable chi_b.chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi_b$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_2ndLaw Notification: Performance of FrontEnd: time 1.289/2.787, allocations: 205.8 MB / 1.507 GB, free: 251.8 MB / 0.8855 GB