startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_7.0.0_Buildings.Experimental.DistrictHeatingCooling.Validation.IdealSmallSystem -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | hea1.pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | hea2.pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | coo1.pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | coo2.pum.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.125963s reading init.xml | | | | | | 0.0119439s reading info.xml | | | | | | 0.000291362s [ 0.1%] pre-initialization | | | | | | 0.000983302s [ 0.2%] initialization | | | | | | 5.7539e-05s [ 0.0%] steps | | | | | | 0.0143178s [ 2.5%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00511293s [ 0.9%] event-handling | | | | | | 0.135952s [ 24.1%] overhead | | | | | | 0.408374s [ 72.3%] simulation | | | | | | 0.565089s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 698 steps taken | | | | | | 915 calls of functionODE | | | | | | 119 evaluations of jacobian | | | | | | 30 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0216376s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.