Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel") translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.106/2.106, allocations: 251.1 MB / 266.7 MB, free: 11.62 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00135/0.00135, allocations: 177.9 kB / 326.2 MB, free: 2.859 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.324/2.324, allocations: 205.4 MB / 0.5772 GB, free: 20.78 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009869/0.0009864, allocations: 91.22 kB / 0.6817 GB, free: 13.62 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0006431/0.0006433, allocations: 15.41 kB / 0.7957 GB, free: 135.5 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2115/0.2122, allocations: 106.3 MB / 0.8995 GB, free: 65.51 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.267/1.48, allocations: 441 MB / 1.33 GB, free: 10.77 MB / 0.8386 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003929/1.48, allocations: 115.7 kB / 1.33 GB, free: 10.7 MB / 0.8386 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Applications/DataCenters/ChillerCooled/Equipment/BaseClasses/PartialPumpParallel.mo:105:11-105:18:writable] Error: Type mismatch in binding hydraulicEfficiency = Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency({0}, {0.7}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[1] V_flow; Real(max = 1.0, quantity = "Efficiency", unit = "1", min = 0.0)[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency Integer[1] V_flow; Real[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel Notification: Performance of FrontEnd: time 1.698/3.178, allocations: 345.6 MB / 1.668 GB, free: 87.54 MB / 0.8855 GB