Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case630.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case630,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case630") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.004259/0.004263, allocations: 234.3 kB / 15.82 MB, free: 6.297 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001247/0.001247, allocations: 175.5 kB / 16.7 MB, free: 5.457 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 3.879/3.879, allocations: 389.1 MB / 406.5 MB, free: 11.85 MB / 330.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 3.725/3.725, allocations: 472.3 MB / 0.9024 GB, free: 18.79 MB / 442.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0006671/0.0006673, allocations: 12.53 kB / 1.008 GB, free: 13.38 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2204/0.2211, allocations: 98.73 MB / 1.105 GB, free: 10.7 MB / 0.573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.742/7.963, allocations: 2.351 GB / 3.456 GB, free: 155.1 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000549/7.964, allocations: 127.5 kB / 3.456 GB, free: 155.1 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/Outside.mo:28:3-31:49:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/PartialSource.mo:38:3-40:49:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg", final quantity = Medium.substanceNames) "Needed to connect to conditional connector" second element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg") "Needed to connect to conditional connector" Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case630 Notification: Performance of FrontEnd: time 0.4462/8.41, allocations: 123.1 MB / 3.576 GB, free: 39.84 MB / 0.823 GB