Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.NaturalConvectionWithControl.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Examples.FFD.NaturalConvectionWithControl,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.NaturalConvectionWithControl") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.004354/0.00436, allocations: 233 kB / 15.82 MB, free: 6.297 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001211/0.001211, allocations: 172.9 kB / 16.7 MB, free: 5.457 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 3.652/3.652, allocations: 389.1 MB / 406.5 MB, free: 6.805 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 4.566/4.566, allocations: 472.3 MB / 0.9024 GB, free: 10.82 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0005157/0.0005159, allocations: 12 kB / 1.008 GB, free: 6.727 MB / 0.6511 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2227/0.2232, allocations: 98.7 MB / 1.105 GB, free: 3.867 MB / 0.7448 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.424/7.647, allocations: 2.318 GB / 3.422 GB, free: 218.6 MB / 0.8386 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003783/7.647, allocations: 108.9 kB / 3.423 GB, free: 218.6 MB / 0.8386 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:248:11-248:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Examples.FFD.NaturalConvectionWithControl Notification: Performance of FrontEnd: time 0.6516/8.299, allocations: 185.6 MB / 3.604 GB, free: 65.95 MB / 0.8386 GB