Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.Examples.Borefields.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.Examples.Borefields,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.Examples.Borefields") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.004134/0.004134, allocations: 234 kB / 15.83 MB, free: 6.293 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.00113/0.00113, allocations: 176.8 kB / 16.71 MB, free: 5.441 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 3.733/3.733, allocations: 389.1 MB / 406.5 MB, free: 11.81 MB / 330.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 3.899/3.899, allocations: 472.3 MB / 0.9024 GB, free: 9.203 MB / 0.5886 GB Notification: Performance of FrontEnd - loaded program: time 0.0006408/0.0006412, allocations: 15.98 kB / 1.008 GB, free: 138.3 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1686/0.1692, allocations: 98.71 MB / 1.105 GB, free: 42.1 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.841/2.01, allocations: 0.4911 GB / 1.596 GB, free: 171.9 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003392/2.01, allocations: 109.3 kB / 1.596 GB, free: 171.8 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Geothermal/Borefields/Examples/Borefields.mo:98:5-98:28:writable] Error: Component borFieUTub.borFieDat of variability PARAM has binding borFieUTubDat of higher variability VAR. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.Examples.Borefields Notification: Performance of FrontEnd: time 0.2859/2.296, allocations: 86.74 MB / 1.681 GB, free: 97.32 MB / 0.823 GB