Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.004231/0.004231, allocations: 231.2 kB / 15.82 MB, free: 6.293 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001092/0.001092, allocations: 175.3 kB / 16.7 MB, free: 5.453 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 3.973/3.973, allocations: 389.1 MB / 406.5 MB, free: 11.82 MB / 330.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 3.932/3.932, allocations: 472.3 MB / 0.9024 GB, free: 9.168 MB / 0.5886 GB Notification: Performance of FrontEnd - loaded program: time 0.000487/0.0004873, allocations: 12 kB / 1.008 GB, free: 138.2 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1814/0.1819, allocations: 98.72 MB / 1.105 GB, free: 42.08 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.541/7.723, allocations: 2.206 GB / 3.31 GB, free: 228.3 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004454/7.724, allocations: 110.5 kB / 3.31 GB, free: 228.3 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels Notification: Performance of FrontEnd: time 0.2784/8.002, allocations: 64.17 MB / 3.373 GB, free: 223.1 MB / 0.823 GB