Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.4.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package BuildSysPro with version 3.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.4.0/package.mo) Running command: translateModel(BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater,tolerance=1e-06,outputFormat="empty",numberOfIntervals=480,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater") translateModel(BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater,tolerance=1e-06,outputFormat="empty",numberOfIntervals=480,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater") [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.4.0/UsersGuide/package.order:0:0-0:0:readonly] Warning: The package.order file does not list all .mo files and directories (containing package.mo) present in its directory. Missing names are: License Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.4.0/package.mo): time 0.819/0.819, allocations: 117.9 MB / 133.9 MB, free: 9.227 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009317/0.0009317, allocations: 176.4 kB / 161.7 MB, free: 13.98 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.721/1.721, allocations: 205.4 MB / 394.8 MB, free: 10.01 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008037/0.0008036, allocations: 86.62 kB / 470.1 MB, free: 29.1 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0005554/0.0005553, allocations: 12 kB / 0.5423 GB, free: 9.766 MB / 410.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1899/0.1905, allocations: 74.53 MB / 0.6151 GB, free: 15.16 MB / 490.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.4.0/Systems/DHW/Examples/DHWResistiveWaterHeater.mo:20:3-21:79:writable] Error: Class Modelica_LinearSystems2.Controller.SampleClock not found in scope BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater. Error: Error occurred while flattening model BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater Notification: Performance of FrontEnd: time 0.4869/0.6775, allocations: 101.1 MB / 0.7138 GB, free: 31.29 MB / 0.4948 GB