Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr AixLib_latest_AixLib.ThermalZones.ReducedOrder.Validation.ASHRAE140.ThreeElements.TestCase950FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 1.7.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_Synchronous 0.93.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo", uses=false) Using package SDF with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo) Using package NcDataReader2 with version 2.5.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.0/package.mo) Using package Modelica_Synchronous with version 0.93.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_Synchronous 0.93.0/package.mo) Using package Modelica_DeviceDrivers with version 1.7.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 1.7.0/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package AixLib with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/package.mo) Running command: translateModel(AixLib.ThermalZones.ReducedOrder.Validation.ASHRAE140.ThreeElements.TestCase950FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="AixLib_latest_AixLib.ThermalZones.ReducedOrder.Validation.ASHRAE140.ThreeElements.TestCase950FF") translateModel(AixLib.ThermalZones.ReducedOrder.Validation.ASHRAE140.ThreeElements.TestCase950FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="AixLib_latest_AixLib.ThermalZones.ReducedOrder.Validation.ASHRAE140.ThreeElements.TestCase950FF") [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Types/Azimuth/package.mo:11:4-12:70:writable] Warning: Elements in the package.mo-file need to be in the same relative order as the package.order file. Got element named NW but it was already added because it was not the next element in the list at that time. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Types/Azimuth/package.mo:11:4-12:70:writable] Warning: Got element NW that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Types/Azimuth/package.mo:13:4-14:65:writable] Warning: Elements in the package.mo-file need to be in the same relative order as the package.order file. Got element named N but it was already added because it was not the next element in the list at that time. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Types/Azimuth/package.mo:13:4-14:65:writable] Warning: Got element N that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Types/Azimuth/package.mo:15:4-16:70:writable] Warning: Elements in the package.mo-file need to be in the same relative order as the package.order file. Got element named NE but it was already added because it was not the next element in the list at that time. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Types/Azimuth/package.mo:15:4-16:70:writable] Warning: Got element NE that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Types/Azimuth/package.mo:17:4-18:64:writable] Warning: Elements in the package.mo-file need to be in the same relative order as the package.order file. Got element named E but it was already added because it was not the next element in the list at that time. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Types/Azimuth/package.mo:17:4-18:64:writable] Warning: Got element E that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Types/Azimuth/package.mo:19:4-20:70:writable] Warning: Elements in the package.mo-file need to be in the same relative order as the package.order file. Got element named SE but it was already added because it was not the next element in the list at that time. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Types/Azimuth/package.mo:19:4-20:70:writable] Warning: Got element SE that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Types/Azimuth/package.mo:2:1-45:12:writable] Warning: SE was referenced in the package.order file, but was not found in package.mo, SE/package.mo or SE.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:9:3-25:68:writable] Warning: Got element refrigerantConstants that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:85:13-94:23:writable] Warning: Got element SmoothTransition that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:97:13-104:12:writable] Warning: Got element f_Idg that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:106:13-128:12:writable] Warning: Got element f_Res that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:130:13-137:15:writable] Warning: Got element t_fIdg_t that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:139:13-148:17:writable] Warning: Got element tt_fIdg_tt that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:150:13-171:15:writable] Warning: Got element t_fRes_t that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:173:13-196:17:writable] Warning: Got element tt_fRes_tt that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:198:13-221:15:writable] Warning: Got element d_fRes_d that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:223:13-256:17:writable] Warning: Got element dd_fRes_dd that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:258:13-284:17:writable] Warning: Got element td_fRes_td that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:286:13-296:19:writable] Warning: Got element ttt_fIdg_ttt that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:298:13-325:19:writable] Warning: Got element ttt_fRes_ttt that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:327:13-373:19:writable] Warning: Got element ddd_fRes_ddd that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:375:13-409:19:writable] Warning: Got element tdd_fRes_tdd that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:411:13-440:19:writable] Warning: Got element ttd_fRes_ttd that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:445:13-466:25:writable] Warning: Got element saturationPressure that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:468:13-490:28:writable] Warning: Got element saturationTemperature that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:492:13-517:20:writable] Warning: Got element bubbleDensity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:519:13-549:17:writable] Warning: Got element dewDensity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:551:13-571:21:writable] Warning: Got element bubbleEnthalpy that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:573:13-594:18:writable] Warning: Got element dewEnthalpy that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:596:13-616:20:writable] Warning: Got element bubbleEntropy that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:618:13-638:17:writable] Warning: Got element dewEntropy that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:643:25-775:21:writable] Warning: Got element temperature_ph that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:777:25-909:21:writable] Warning: Got element temperature_ps that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:911:25-1069:17:writable] Warning: Got element density_pT that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:1073:13-1142:23:writable] Warning: Got element dynamicViscosity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:1144:13-1210:26:writable] Warning: Got element thermalConductivity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Horner/package.mo:1212:13-1226:21:writable] Warning: Got element surfaceTension that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:8:3-24:68:writable] Warning: Got element refrigerantConstants that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:84:13-93:23:writable] Warning: Got element SmoothTransition that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:96:13-103:12:writable] Warning: Got element f_Idg that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:105:13-127:12:writable] Warning: Got element f_Res that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:129:13-136:15:writable] Warning: Got element t_fIdg_t that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:138:13-147:17:writable] Warning: Got element tt_fIdg_tt that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:149:13-170:15:writable] Warning: Got element t_fRes_t that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:172:13-195:17:writable] Warning: Got element tt_fRes_tt that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:197:13-220:15:writable] Warning: Got element d_fRes_d that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:222:13-255:17:writable] Warning: Got element dd_fRes_dd that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:257:13-283:17:writable] Warning: Got element td_fRes_td that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:285:13-295:19:writable] Warning: Got element ttt_fIdg_ttt that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:297:13-324:19:writable] Warning: Got element ttt_fRes_ttt that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:326:13-372:19:writable] Warning: Got element ddd_fRes_ddd that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:374:13-408:19:writable] Warning: Got element tdd_fRes_tdd that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:410:13-439:19:writable] Warning: Got element ttd_fRes_ttd that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:444:13-465:25:writable] Warning: Got element saturationPressure that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:467:13-488:28:writable] Warning: Got element saturationTemperature that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:490:13-520:20:writable] Warning: Got element bubbleDensity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:522:13-550:17:writable] Warning: Got element dewDensity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:552:13-575:21:writable] Warning: Got element bubbleEnthalpy that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:577:13-601:18:writable] Warning: Got element dewEnthalpy that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:603:13-626:20:writable] Warning: Got element bubbleEntropy that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:628:13-651:17:writable] Warning: Got element dewEntropy that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:656:25-803:21:writable] Warning: Got element temperature_ph that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:805:25-951:21:writable] Warning: Got element temperature_ps that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:953:25-1141:17:writable] Warning: Got element density_pT that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:1145:13-1214:23:writable] Warning: Got element dynamicViscosity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:1216:13-1282:26:writable] Warning: Got element thermalConductivity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_473_Formula/package.mo:1284:13-1298:21:writable] Warning: Got element surfaceTension that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Record/package.mo:8:3-24:68:writable] Warning: Got element refrigerantConstants that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Record/package.mo:84:13-87:10:writable] Warning: Got element EoS that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Record/package.mo:89:13-93:11:writable] Warning: Got element BDSP that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Record/package.mo:95:13-99:10:writable] Warning: Got element TSP that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Record/package.mo:101:13-110:23:writable] Warning: Got element SmoothTransition that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Record/package.mo:114:13-183:23:writable] Warning: Got element dynamicViscosity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Record/package.mo:185:13-251:26:writable] Warning: Got element thermalConductivity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Record/package.mo:253:13-267:21:writable] Warning: Got element surfaceTension that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:8:3-24:68:writable] Warning: Got element refrigerantConstants that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:84:13-93:23:writable] Warning: Got element SmoothTransition that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:96:13-103:12:writable] Warning: Got element f_Idg that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:105:13-127:12:writable] Warning: Got element f_Res that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:129:13-136:15:writable] Warning: Got element t_fIdg_t that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:138:13-147:17:writable] Warning: Got element tt_fIdg_tt that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:149:13-170:15:writable] Warning: Got element t_fRes_t that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:172:13-195:17:writable] Warning: Got element tt_fRes_tt that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:197:13-220:15:writable] Warning: Got element d_fRes_d that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:222:13-255:17:writable] Warning: Got element dd_fRes_dd that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:257:13-283:17:writable] Warning: Got element td_fRes_td that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:285:13-295:19:writable] Warning: Got element ttt_fIdg_ttt that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:297:13-324:19:writable] Warning: Got element ttt_fRes_ttt that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:326:13-372:19:writable] Warning: Got element ddd_fRes_ddd that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:374:13-408:19:writable] Warning: Got element tdd_fRes_tdd that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:410:13-439:19:writable] Warning: Got element ttd_fRes_ttd that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:444:13-465:25:writable] Warning: Got element saturationPressure that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:467:13-488:28:writable] Warning: Got element saturationTemperature that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:490:13-520:20:writable] Warning: Got element bubbleDensity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:522:13-550:17:writable] Warning: Got element dewDensity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:552:13-575:21:writable] Warning: Got element bubbleEnthalpy that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:577:13-601:18:writable] Warning: Got element dewEnthalpy that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:603:13-626:20:writable] Warning: Got element bubbleEntropy that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:628:13-651:17:writable] Warning: Got element dewEntropy that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:656:25-804:21:writable] Warning: Got element temperature_ph that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:806:25-953:21:writable] Warning: Got element temperature_ps that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:955:25-1099:17:writable] Warning: Got element density_pT that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:1103:13-1172:23:writable] Warning: Got element dynamicViscosity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:1174:13-1240:26:writable] Warning: Got element thermalConductivity that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A_HEoS/R410a_IIR_P1_48_T233_340_Formula/package.mo:1242:13-1256:21:writable] Warning: Got element surfaceTension that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A/package.mo:18:3-19:54:writable] Warning: Got element A that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A/package.mo:21:3-22:54:writable] Warning: Got element B that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A/package.mo:24:3-25:54:writable] Warning: Got element C that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A/package.mo:27:3-28:53:writable] Warning: Elements in the package.mo-file need to be in the same relative order as the package.order file. Got element named b but it was already added because it was not the next element in the list at that time. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A/package.mo:27:3-28:53:writable] Warning: Got element b that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A/package.mo:30:3-31:53:writable] Warning: Elements in the package.mo-file need to be in the same relative order as the package.order file. Got element named k but it was already added because it was not the next element in the list at that time. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A/package.mo:30:3-31:53:writable] Warning: Got element k that was not referenced in the package.order file. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Media/Refrigerants/R410A/package.mo:2:1-71:10:writable] Warning: k was referenced in the package.order file, but was not found in package.mo, k/package.mo or k.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Fluid/HeatExchangers/Radiators/BaseClasses/package.order:0:0-0:0:readonly] Warning: Found duplicate names in package.order file: RadiatorTypes. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/Electrical/Machines/package.order:0:0-0:0:readonly] Warning: Found duplicate names in package.order file: PVInverterRMS. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/package.mo): time 1.455/1.455, allocations: 257.8 MB / 273.7 MB, free: 14.88 MB / 234.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001094/0.001094, allocations: 179.7 kB / 329.3 MB, free: 13.29 MB / 266.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.351/1.351, allocations: 205.4 MB / 0.5763 GB, free: 15.45 MB / 458.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008792/0.0008792, allocations: 91.64 kB / 0.6769 GB, free: 15.75 MB / 474.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 1.7.0/package.mo): time 0.04792/0.04792, allocations: 10.75 MB / 0.788 GB, free: 14.33 MB / 0.573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_Synchronous 0.93.0/package.mo): time 0.06078/0.06078, allocations: 12.21 MB / 0.903 GB, free: 139.7 MB / 0.6043 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.0/package.mo): time 0.001806/0.001805, allocations: 270.1 kB / 1.009 GB, free: 31.11 MB / 0.6043 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo): time 0.0002831/0.0002832, allocations: 12.61 kB / 1.115 GB, free: 170.6 MB / 0.6355 GB Warning: Requested package Modelica_Synchronous of version 0.92.2, but this package was already loaded with version 0.93.0. There are no conversion annotations and 0.92.2 is older than 0.93.0, so the libraries are probably incompatible. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 1.7.0/package.mo:11:16-11:38:writable] Warning: Conversion-annotation contains unknown element: nonFromVersion. Warning: Requested package Modelica_Synchronous of version 0.92.1, but this package was already loaded with version 0.93.0. There are no conversion annotations and 0.92.1 is older than 0.93.0, so the libraries are probably incompatible. Notification: Performance of FrontEnd - loaded program: time 0.001099/0.001099, allocations: 46.41 kB / 1.236 GB, free: 50.09 MB / 0.6355 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6089/0.61, allocations: 107.6 MB / 1.341 GB, free: 81.84 MB / 0.6824 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.484/5.094, allocations: 2.48 GB / 3.821 GB, free: 18.08 MB / 0.9324 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002319/5.095, allocations: 99.94 kB / 3.821 GB, free: 17.98 MB / 0.9324 GB Notification: Performance of FrontEnd - DAE generated: time 1.096/6.191, allocations: 360.2 MB / 4.172 GB, free: 42.96 MB / 0.9324 GB Notification: Performance of FrontEnd: time 2.234e-06/6.191, allocations: 0 / 4.172 GB, free: 42.96 MB / 0.9324 GB Notification: Performance of Transformations before backend: time 0.0004911/6.192, allocations: 120 kB / 4.173 GB, free: 42.84 MB / 0.9324 GB Error: Too many equations, over-determined system. The model has 1391 equation(s) and 1247 variable(s). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1070 (size: 1) HDifTil[1].weaBus.HDifHor = HDirTil[3].weaBus.HDifHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HDifHor Equations used to solve those variables: Equation 1069 (size: 1): HDifTil[1].weaBus.HDifHor = HDirTil[2].weaBus.HDifHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1071 (size: 1) HDifTil[1].weaBus.HDifHor = HDirTil[4].weaBus.HDifHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HDifHor Equations used to solve those variables: Equation 1069 (size: 1): HDifTil[1].weaBus.HDifHor = HDirTil[2].weaBus.HDifHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1072 (size: 1) HDifTil[1].weaBus.HDifHor = HDirTil[5].weaBus.HDifHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HDifHor Equations used to solve those variables: Equation 1069 (size: 1): HDifTil[1].weaBus.HDifHor = HDirTil[2].weaBus.HDifHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1076 (size: 1) HDifTil[1].weaBus.HDirNor = HDifTil[3].weaBus.HDirNor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HDirNor Equations used to solve those variables: Equation 1075 (size: 1): HDifTil[1].weaBus.HDirNor = HDifTil[2].weaBus.HDirNor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1077 (size: 1) HDifTil[1].weaBus.HDirNor = HDifTil[4].weaBus.HDirNor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HDirNor Equations used to solve those variables: Equation 1075 (size: 1): HDifTil[1].weaBus.HDirNor = HDifTil[2].weaBus.HDirNor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1078 (size: 1) HDifTil[1].weaBus.HDirNor = HDifTil[5].weaBus.HDirNor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HDirNor Equations used to solve those variables: Equation 1075 (size: 1): HDifTil[1].weaBus.HDirNor = HDifTil[2].weaBus.HDirNor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1092 (size: 1) HDifTil[1].weaBus.HGloHor = HDirTil[3].weaBus.HGloHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HGloHor Equations used to solve those variables: Equation 1091 (size: 1): HDifTil[1].weaBus.HGloHor = HDirTil[2].weaBus.HGloHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1093 (size: 1) HDifTil[1].weaBus.HGloHor = HDirTil[4].weaBus.HGloHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HGloHor Equations used to solve those variables: Equation 1091 (size: 1): HDifTil[1].weaBus.HGloHor = HDirTil[2].weaBus.HGloHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1094 (size: 1) HDifTil[1].weaBus.HGloHor = HDirTil[5].weaBus.HGloHor is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HGloHor Equations used to solve those variables: Equation 1091 (size: 1): HDifTil[1].weaBus.HGloHor = HDirTil[2].weaBus.HGloHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1098 (size: 1) HDifTil[1].weaBus.HHorIR = HDifTil[3].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1097 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1099 (size: 1) HDifTil[1].weaBus.HHorIR = HDifTil[4].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1097 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1100 (size: 1) HDifTil[1].weaBus.HHorIR = HDifTil[5].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1097 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1102 (size: 1) HDifTil[1].weaBus.HHorIR = HDirTil[2].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1097 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1103 (size: 1) HDifTil[1].weaBus.HHorIR = HDirTil[3].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1097 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1104 (size: 1) HDifTil[1].weaBus.HHorIR = HDirTil[4].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1097 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1105 (size: 1) HDifTil[1].weaBus.HHorIR = HDirTil[5].weaBus.HHorIR is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.HHorIR Equations used to solve those variables: Equation 1097 (size: 1): HDifTil[1].weaBus.HHorIR = HDifTil[2].weaBus.HHorIR [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1109 (size: 1) HDifTil[1].weaBus.TBlaSky = HDifTil[3].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1108 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1110 (size: 1) HDifTil[1].weaBus.TBlaSky = HDifTil[4].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1108 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1111 (size: 1) HDifTil[1].weaBus.TBlaSky = HDifTil[5].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1108 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1113 (size: 1) HDifTil[1].weaBus.TBlaSky = HDirTil[2].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1108 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1114 (size: 1) HDifTil[1].weaBus.TBlaSky = HDirTil[3].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1108 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1115 (size: 1) HDifTil[1].weaBus.TBlaSky = HDirTil[4].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1108 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1116 (size: 1) HDifTil[1].weaBus.TBlaSky = HDirTil[5].weaBus.TBlaSky is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TBlaSky Equations used to solve those variables: Equation 1108 (size: 1): HDifTil[1].weaBus.TBlaSky = HDifTil[2].weaBus.TBlaSky [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1121 (size: 1) HDifTil[1].weaBus.TDewPoi = HDifTil[3].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1120 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1122 (size: 1) HDifTil[1].weaBus.TDewPoi = HDifTil[4].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1120 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1123 (size: 1) HDifTil[1].weaBus.TDewPoi = HDifTil[5].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1120 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1125 (size: 1) HDifTil[1].weaBus.TDewPoi = HDirTil[2].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1120 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1126 (size: 1) HDifTil[1].weaBus.TDewPoi = HDirTil[3].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1120 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1127 (size: 1) HDifTil[1].weaBus.TDewPoi = HDirTil[4].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1120 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1128 (size: 1) HDifTil[1].weaBus.TDewPoi = HDirTil[5].weaBus.TDewPoi is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDewPoi Equations used to solve those variables: Equation 1120 (size: 1): HDifTil[1].weaBus.TDewPoi = HDifTil[2].weaBus.TDewPoi [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1132 (size: 1) HDifTil[1].weaBus.TDryBul = HDifTil[3].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1131 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1133 (size: 1) HDifTil[1].weaBus.TDryBul = HDifTil[4].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1131 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1134 (size: 1) HDifTil[1].weaBus.TDryBul = HDifTil[5].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1131 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1136 (size: 1) HDifTil[1].weaBus.TDryBul = HDirTil[2].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1131 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1137 (size: 1) HDifTil[1].weaBus.TDryBul = HDirTil[3].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1131 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1138 (size: 1) HDifTil[1].weaBus.TDryBul = HDirTil[4].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1131 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1139 (size: 1) HDifTil[1].weaBus.TDryBul = HDirTil[5].weaBus.TDryBul is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.TDryBul Equations used to solve those variables: Equation 1131 (size: 1): HDifTil[1].weaBus.TDryBul = HDifTil[2].weaBus.TDryBul [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1145 (size: 1) HDifTil[1].weaBus.ceiHei = HDifTil[3].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1144 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1146 (size: 1) HDifTil[1].weaBus.ceiHei = HDifTil[4].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1144 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1147 (size: 1) HDifTil[1].weaBus.ceiHei = HDifTil[5].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1144 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1149 (size: 1) HDifTil[1].weaBus.ceiHei = HDirTil[2].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1144 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1150 (size: 1) HDifTil[1].weaBus.ceiHei = HDirTil[3].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1144 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1151 (size: 1) HDifTil[1].weaBus.ceiHei = HDirTil[4].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1144 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1152 (size: 1) HDifTil[1].weaBus.ceiHei = HDirTil[5].weaBus.ceiHei is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.ceiHei Equations used to solve those variables: Equation 1144 (size: 1): HDifTil[1].weaBus.ceiHei = HDifTil[2].weaBus.ceiHei [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1167 (size: 1) HDifTil[1].weaBus.lat = HDifTil[3].weaBus.lat is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lat Equations used to solve those variables: Equation 1166 (size: 1): HDifTil[1].weaBus.lat = HDifTil[2].weaBus.lat [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1168 (size: 1) HDifTil[1].weaBus.lat = HDifTil[4].weaBus.lat is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lat Equations used to solve those variables: Equation 1166 (size: 1): HDifTil[1].weaBus.lat = HDifTil[2].weaBus.lat [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1169 (size: 1) HDifTil[1].weaBus.lat = HDifTil[5].weaBus.lat is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lat Equations used to solve those variables: Equation 1166 (size: 1): HDifTil[1].weaBus.lat = HDifTil[2].weaBus.lat [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1171 (size: 1) HDifTil[1].weaBus.lat = HDirTil[2].weaBus.lat is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lat Equations used to solve those variables: Equation 1166 (size: 1): HDifTil[1].weaBus.lat = HDifTil[2].weaBus.lat [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1172 (size: 1) HDifTil[1].weaBus.lat = HDirTil[3].weaBus.lat is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lat Equations used to solve those variables: Equation 1166 (size: 1): HDifTil[1].weaBus.lat = HDifTil[2].weaBus.lat [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1173 (size: 1) HDifTil[1].weaBus.lat = HDirTil[4].weaBus.lat is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lat Equations used to solve those variables: Equation 1166 (size: 1): HDifTil[1].weaBus.lat = HDifTil[2].weaBus.lat [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1174 (size: 1) HDifTil[1].weaBus.lat = HDirTil[5].weaBus.lat is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lat Equations used to solve those variables: Equation 1166 (size: 1): HDifTil[1].weaBus.lat = HDifTil[2].weaBus.lat [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1176 (size: 1) HDifTil[1].weaBus.lat = weaDat.weaBus.lat is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.weaBus.lat, HDifTil[1].weaBus.lat Equations used to solve those variables: Equation 719 (size: 1): weaDat.latitude.y = weaDat.weaBus.lat Equation 1166 (size: 1): HDifTil[1].weaBus.lat = HDifTil[2].weaBus.lat [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1178 (size: 1) HDifTil[1].weaBus.lon = HDifTil[3].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1177 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1179 (size: 1) HDifTil[1].weaBus.lon = HDifTil[4].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1177 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1180 (size: 1) HDifTil[1].weaBus.lon = HDifTil[5].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1177 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1182 (size: 1) HDifTil[1].weaBus.lon = HDirTil[2].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1177 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1183 (size: 1) HDifTil[1].weaBus.lon = HDirTil[3].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1177 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1184 (size: 1) HDifTil[1].weaBus.lon = HDirTil[4].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1177 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1185 (size: 1) HDifTil[1].weaBus.lon = HDirTil[5].weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 1177 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1187 (size: 1) HDifTil[1].weaBus.lon = weaDat.weaBus.lon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.weaBus.lon, HDifTil[1].weaBus.lon Equations used to solve those variables: Equation 718 (size: 1): weaDat.longitude.y = weaDat.weaBus.lon Equation 1177 (size: 1): HDifTil[1].weaBus.lon = HDifTil[2].weaBus.lon [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1189 (size: 1) HDifTil[1].weaBus.nOpa = HDifTil[3].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1188 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1190 (size: 1) HDifTil[1].weaBus.nOpa = HDifTil[4].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1188 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1191 (size: 1) HDifTil[1].weaBus.nOpa = HDifTil[5].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1188 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1193 (size: 1) HDifTil[1].weaBus.nOpa = HDirTil[2].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1188 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1194 (size: 1) HDifTil[1].weaBus.nOpa = HDirTil[3].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1188 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1195 (size: 1) HDifTil[1].weaBus.nOpa = HDirTil[4].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1188 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1196 (size: 1) HDifTil[1].weaBus.nOpa = HDirTil[5].weaBus.nOpa is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nOpa Equations used to solve those variables: Equation 1188 (size: 1): HDifTil[1].weaBus.nOpa = HDifTil[2].weaBus.nOpa [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1200 (size: 1) HDifTil[1].weaBus.nTot = HDifTil[3].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1199 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1201 (size: 1) HDifTil[1].weaBus.nTot = HDifTil[4].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1199 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1202 (size: 1) HDifTil[1].weaBus.nTot = HDifTil[5].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1199 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1204 (size: 1) HDifTil[1].weaBus.nTot = HDirTil[2].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1199 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1205 (size: 1) HDifTil[1].weaBus.nTot = HDirTil[3].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1199 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1206 (size: 1) HDifTil[1].weaBus.nTot = HDirTil[4].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1199 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1207 (size: 1) HDifTil[1].weaBus.nTot = HDirTil[5].weaBus.nTot is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.nTot Equations used to solve those variables: Equation 1199 (size: 1): HDifTil[1].weaBus.nTot = HDifTil[2].weaBus.nTot [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1211 (size: 1) HDifTil[1].weaBus.pAtm = HDifTil[3].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1210 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1212 (size: 1) HDifTil[1].weaBus.pAtm = HDifTil[4].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1210 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1213 (size: 1) HDifTil[1].weaBus.pAtm = HDifTil[5].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1210 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1215 (size: 1) HDifTil[1].weaBus.pAtm = HDirTil[2].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1210 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1216 (size: 1) HDifTil[1].weaBus.pAtm = HDirTil[3].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1210 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1217 (size: 1) HDifTil[1].weaBus.pAtm = HDirTil[4].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1210 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1218 (size: 1) HDifTil[1].weaBus.pAtm = HDirTil[5].weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.pAtm Equations used to solve those variables: Equation 1210 (size: 1): HDifTil[1].weaBus.pAtm = HDifTil[2].weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1222 (size: 1) HDifTil[1].weaBus.relHum = HDifTil[3].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1221 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1223 (size: 1) HDifTil[1].weaBus.relHum = HDifTil[4].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1221 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1224 (size: 1) HDifTil[1].weaBus.relHum = HDifTil[5].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1221 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1226 (size: 1) HDifTil[1].weaBus.relHum = HDirTil[2].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1221 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1227 (size: 1) HDifTil[1].weaBus.relHum = HDirTil[3].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1221 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1228 (size: 1) HDifTil[1].weaBus.relHum = HDirTil[4].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1221 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1229 (size: 1) HDifTil[1].weaBus.relHum = HDirTil[5].weaBus.relHum is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.relHum Equations used to solve those variables: Equation 1221 (size: 1): HDifTil[1].weaBus.relHum = HDifTil[2].weaBus.relHum [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1233 (size: 1) HDifTil[1].weaBus.solAlt = HDifTil[3].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1232 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1234 (size: 1) HDifTil[1].weaBus.solAlt = HDifTil[4].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1232 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1235 (size: 1) HDifTil[1].weaBus.solAlt = HDifTil[5].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1232 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1237 (size: 1) HDifTil[1].weaBus.solAlt = HDirTil[2].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1232 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1238 (size: 1) HDifTil[1].weaBus.solAlt = HDirTil[3].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1232 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1239 (size: 1) HDifTil[1].weaBus.solAlt = HDirTil[4].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1232 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1240 (size: 1) HDifTil[1].weaBus.solAlt = HDirTil[5].weaBus.solAlt is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solAlt Equations used to solve those variables: Equation 1232 (size: 1): HDifTil[1].weaBus.solAlt = HDifTil[2].weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1244 (size: 1) HDifTil[1].weaBus.solDec = HDifTil[3].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1243 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1245 (size: 1) HDifTil[1].weaBus.solDec = HDifTil[4].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1243 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1246 (size: 1) HDifTil[1].weaBus.solDec = HDifTil[5].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1243 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1248 (size: 1) HDifTil[1].weaBus.solDec = HDirTil[2].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1243 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1249 (size: 1) HDifTil[1].weaBus.solDec = HDirTil[3].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1243 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1250 (size: 1) HDifTil[1].weaBus.solDec = HDirTil[4].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1243 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1251 (size: 1) HDifTil[1].weaBus.solDec = HDirTil[5].weaBus.solDec is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solDec Equations used to solve those variables: Equation 1243 (size: 1): HDifTil[1].weaBus.solDec = HDifTil[2].weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1255 (size: 1) HDifTil[1].weaBus.solHouAng = HDifTil[3].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1254 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1256 (size: 1) HDifTil[1].weaBus.solHouAng = HDifTil[4].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1254 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1257 (size: 1) HDifTil[1].weaBus.solHouAng = HDifTil[5].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1254 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1259 (size: 1) HDifTil[1].weaBus.solHouAng = HDirTil[2].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1254 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1260 (size: 1) HDifTil[1].weaBus.solHouAng = HDirTil[3].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1254 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1261 (size: 1) HDifTil[1].weaBus.solHouAng = HDirTil[4].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1254 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1262 (size: 1) HDifTil[1].weaBus.solHouAng = HDirTil[5].weaBus.solHouAng is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solHouAng Equations used to solve those variables: Equation 1254 (size: 1): HDifTil[1].weaBus.solHouAng = HDifTil[2].weaBus.solHouAng [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1282 (size: 1) HDifTil[1].weaBus.solZen = HDirTil[3].weaBus.solZen is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solZen Equations used to solve those variables: Equation 1281 (size: 1): HDifTil[1].weaBus.solZen = HDirTil[2].weaBus.solZen [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1283 (size: 1) HDifTil[1].weaBus.solZen = HDirTil[4].weaBus.solZen is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solZen Equations used to solve those variables: Equation 1281 (size: 1): HDifTil[1].weaBus.solZen = HDirTil[2].weaBus.solZen [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1284 (size: 1) HDifTil[1].weaBus.solZen = HDirTil[5].weaBus.solZen is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.solZen Equations used to solve those variables: Equation 1281 (size: 1): HDifTil[1].weaBus.solZen = HDirTil[2].weaBus.solZen [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1288 (size: 1) HDifTil[1].weaBus.winDir = HDifTil[3].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1287 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1289 (size: 1) HDifTil[1].weaBus.winDir = HDifTil[4].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1287 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1290 (size: 1) HDifTil[1].weaBus.winDir = HDifTil[5].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1287 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1292 (size: 1) HDifTil[1].weaBus.winDir = HDirTil[2].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1287 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1293 (size: 1) HDifTil[1].weaBus.winDir = HDirTil[3].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1287 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1294 (size: 1) HDifTil[1].weaBus.winDir = HDirTil[4].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1287 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1295 (size: 1) HDifTil[1].weaBus.winDir = HDirTil[5].weaBus.winDir is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winDir Equations used to solve those variables: Equation 1287 (size: 1): HDifTil[1].weaBus.winDir = HDifTil[2].weaBus.winDir [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1299 (size: 1) HDifTil[1].weaBus.winSpe = HDifTil[3].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1298 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1300 (size: 1) HDifTil[1].weaBus.winSpe = HDifTil[4].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1298 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1301 (size: 1) HDifTil[1].weaBus.winSpe = HDifTil[5].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1298 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1303 (size: 1) HDifTil[1].weaBus.winSpe = HDirTil[2].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1298 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1304 (size: 1) HDifTil[1].weaBus.winSpe = HDirTil[3].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1298 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1305 (size: 1) HDifTil[1].weaBus.winSpe = HDirTil[4].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1298 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/ThermalZones/ReducedOrder/Validation/ASHRAE140/ThreeElements/TestCase950FF.mo:222:3-226:20:writable] Warning: Equation 1306 (size: 1) HDifTil[1].weaBus.winSpe = HDirTil[5].weaBus.winSpe is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: HDifTil[1].weaBus.winSpe Equations used to solve those variables: Equation 1298 (size: 1): HDifTil[1].weaBus.winSpe = HDifTil[2].weaBus.winSpe [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/WeatherData/ReaderTMY3.mo:813:3-818:47:writable] Warning: Equation 720 (size: 1) weaDat.chePre.pAtm = weaDat.weaBus.pAtm is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.chePre.pAtm, weaDat.weaBus.pAtm Equations used to solve those variables: Equation 34 (size: 1): weaDat.chePre.pAtm = weaDat.chePre.PIn Equation 1220 (size: 1): HDifTil[1].weaBus.pAtm = weaDat.weaBus.pAtm [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/SolarGeometry/BaseClasses/AltitudeAngle.mo:13:3-13:40:writable] Warning: Equation 57 (size: 1) weaDat.altAng.alt = 1.570796326794897 - weaDat.altAng.zen is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.altAng.zen, weaDat.altAng.alt Equations used to solve those variables: Equation 673 (size: 1): weaDat.altAng.zen = weaDat.weaBus.solZen Equation 717 (size: 1): weaDat.altAng.alt = weaDat.weaBus.solAlt [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/SolarGeometry/BaseClasses/ZenithAngle.mo:18:3-20:22:writable] Warning: Equation 58 (size: 1) weaDat.zenAng.zen = acos(cos(weaDat.zenAng.lat) * cos(weaDat.zenAng.decAng) * cos(weaDat.zenAng.solHouAng) + sin(weaDat.zenAng.lat) * sin(weaDat.zenAng.decAng)) is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.zenAng.solHouAng, weaDat.zenAng.decAng, weaDat.zenAng.zen Equations used to solve those variables: Equation 667 (size: 1): weaDat.decAng.decAng = weaDat.zenAng.decAng Equation 669 (size: 1): weaDat.solHouAng.solHouAng = weaDat.zenAng.solHouAng Equation 674 (size: 1): weaDat.altAng.zen = weaDat.zenAng.zen [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/SolarGeometry/BaseClasses/Declination.mo:16:3-17:13:writable] Warning: Equation 59 (size: 1) weaDat.decAng.decAng = asin((-0.3979486313076103) * cos(0.01720242383895848 * (10.0 + 1.157407407407407e-05 * weaDat.decAng.nDay))) is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.decAng.nDay, weaDat.decAng.decAng Equations used to solve those variables: Equation 651 (size: 1): weaDat.add30Min.u2 = weaDat.decAng.nDay Equation 666 (size: 1): weaDat.decAng.decAng = weaDat.weaBus.solDec [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/WeatherData/ReaderTMY3.mo:660:3-662:80:writable] Warning: Equation 699 (size: 1) weaDat.HDirNor_in = weaDat.souSelRad.HDirNorIn is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.souSelRad.HDirNorIn, weaDat.HDirNor_in Equations used to solve those variables: Equation 646 (size: 1): weaDat.souSelRad.HDirNorIn = weaDat.souSelRad.HDirNor_in_internal Equation 1379 (size: 1): souRad.y[1] = weaDat.HDirNor_in [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/WeatherData/ReaderTMY3.mo:663:3-665:80:writable] Warning: Equation 700 (size: 1) weaDat.HGloHor_in = weaDat.souSelRad.HGloHorIn is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.souSelRad.HGloHorIn, weaDat.HGloHor_in Equations used to solve those variables: Equation 645 (size: 1): weaDat.souSelRad.HGloHorIn = weaDat.souSelRad.HGloHor_in_internal Equation 1380 (size: 1): souRad.y[2] = weaDat.HGloHor_in [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/WeatherData/BaseClasses/SourceSelectorRadiation.mo:125:5-126:91:writable] Warning: Equation 29 (size: 1) weaDat.souSelRad.HDifHor = max(0.0, weaDat.souSelRad.HGloHor_in_internal - weaDat.souSelRad.HDirNor_in_internal * cos(weaDat.souSelRad.zen)) is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.souSelRad.zen, weaDat.souSelRad.HDifHor, weaDat.souSelRad.HGloHor_in_internal, weaDat.souSelRad.HDirNor_in_internal Equations used to solve those variables: Equation 28 (size: 1): weaDat.souSelRad.HGloHor = max(0.0, weaDat.souSelRad.HGloHor_in_internal) Equation 31 (size: 1): weaDat.souSelRad.HDirNor = max(0.0, weaDat.souSelRad.HDirNor_in_internal) Equation 672 (size: 1): weaDat.altAng.zen = weaDat.souSelRad.zen Equation 710 (size: 1): weaDat.souSelRad.HDifHor = weaDat.weaBus.HDifHor [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/WeatherData/BaseClasses/SolarTime.mo:16:3-16:68:writable] Warning: Equation 53 (size: 1) weaDat.solTim.solTim = weaDat.solTim.locTim + weaDat.solTim.equTim is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.solTim.locTim, weaDat.solTim.equTim, weaDat.solTim.solTim Equations used to solve those variables: Equation 660 (size: 1): weaDat.eqnTim.eqnTim = weaDat.solTim.equTim Equation 661 (size: 1): weaDat.locTim.locTim = weaDat.solTim.locTim Equation 670 (size: 1): weaDat.solHouAng.solTim = weaDat.solTim.solTim [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/WeatherData/BaseClasses/SourceSelector.mo:23:3-23:19:writable] Warning: Equation 640 (size: 1) weaDat.TBlaSkySel.uFil = weaDat.TBlaSkySel.y is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.TBlaSkySel.y, weaDat.TBlaSkySel.uFil Equations used to solve those variables: Equation 682 (size: 1): weaDat.TBlaSkySel.y = weaDat.cheTemBlaSky.TIn Equation 683 (size: 1): weaDat.TBlaSkyCom.TBlaSky = weaDat.TBlaSkySel.uFil [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/WeatherData/ReaderTMY3.mo:592:3-593:71:writable] Warning: Equation 680 (size: 1) weaDat.TDryBulSel.y = weaDat.cheTemDryBul.TIn is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.TDryBulSel.y, weaDat.cheTemDryBul.TIn Equations used to solve those variables: Equation 32 (size: 1): weaDat.cheTemDryBul.TDryBul = weaDat.cheTemDryBul.TIn Equation 638 (size: 1): weaDat.TDryBulSel.uCon = weaDat.TDryBulSel.y [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/WeatherData/ReaderTMY3.mo:619:3-620:55:writable] Warning: Equation 688 (size: 1) weaDat.ceiHeiSel.uFil = weaDat.datRea.y[16] is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.datRea.y[16], weaDat.ceiHeiSel.uFil Equations used to solve those variables: Equation 16 (size: 1): weaDat.datRea.y[16] = Modelica.Blocks.Tables.Internal.getTable1DValue(weaDat.datRea.tableID, 16, weaDat.datRea.u) Equation 647 (size: 1): weaDat.ceiHeiSel.uFil = weaDat.ceiHeiSel.y [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/WeatherData/ReaderTMY3.mo:633:3-634:55:writable] Warning: Equation 693 (size: 1) weaDat.datRea.y[12] = weaDat.winSpeSel.uFil is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.datRea.y[12], weaDat.winSpeSel.uFil Equations used to solve those variables: Equation 12 (size: 1): weaDat.datRea.y[12] = Modelica.Blocks.Tables.Internal.getTable1DValue(weaDat.datRea.tableID, 12, weaDat.datRea.u) Equation 642 (size: 1): weaDat.winSpeSel.uFil = weaDat.winSpeSel.y [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Math.mo:145:7-145:37:writable] Warning: Equation 54 (size: 1) weaDat.conWinDir.y = Modelica.SIunits.Conversions.from_deg(weaDat.conWinDir.u) is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.conWinDir.u, weaDat.conWinDir.y Equations used to solve those variables: Equation 662 (size: 1): weaDat.conWinDir.u = weaDat.datRea.y[11] Equation 695 (size: 1): weaDat.conWinDir.y = weaDat.winDirSel.uFil [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Math.mo:552:5-552:12:writable] Warning: Equation 64 (size: 1) weaDat.conRelHum.y = weaDat.conRelHum.k * weaDat.conRelHum.u is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.conRelHum.u, weaDat.conRelHum.y Equations used to solve those variables: Equation 665 (size: 1): weaDat.conRelHum.u = weaDat.datRea.y[3] Equation 685 (size: 1): weaDat.conRelHum.y = weaDat.relHumSel.uFil [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Math.mo:552:5-552:12:writable] Warning: Equation 69 (size: 1) weaDat.conTotSkyCov.y = weaDat.conTotSkyCov.k * weaDat.conTotSkyCov.u is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.conTotSkyCov.u, weaDat.conTotSkyCov.y Equations used to solve those variables: Equation 689 (size: 1): weaDat.conTotSkyCov.y = weaDat.totSkyCovSel.uFil Equation 692 (size: 1): weaDat.conTotSkyCov.u = weaDat.datRea.y[13] [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/WeatherData/ReaderTMY3.mo:588:3-589:56:writable] Warning: Equation 679 (size: 1) weaDat.TDewPoiSel.uFil = weaDat.conTDewPoi.y is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.TDewPoiSel.uFil, weaDat.conTDewPoi.y Equations used to solve those variables: Equation 56 (size: 1): weaDat.conTDewPoi.y = Modelica.SIunits.Conversions.from_degC(weaDat.conTDewPoi.u) Equation 639 (size: 1): weaDat.TDewPoiSel.uFil = weaDat.TDewPoiSel.y [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/WeatherData/ReaderTMY3.mo:612:3-614:70:writable] Warning: Equation 686 (size: 1) weaDat.conOpaSkyCov.y = weaDat.opaSkyCovSel.uFil is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.opaSkyCovSel.uFil, weaDat.conOpaSkyCov.y Equations used to solve those variables: Equation 70 (size: 1): weaDat.conOpaSkyCov.y = weaDat.conOpaSkyCov.k * weaDat.conOpaSkyCov.u Equation 649 (size: 1): weaDat.opaSkyCovSel.uFil = weaDat.opaSkyCovSel.y [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.0.0-master/BoundaryConditions/WeatherData/ReaderTMY3.mo:650:3-651:59:writable] Warning: Equation 698 (size: 1) weaDat.HInfHor_in = weaDat.horInfRadSel.uCon is not big enough to solve for enough variables. Remaining unsolved variables are: Already solved: weaDat.horInfRadSel.uCon, weaDat.HInfHor_in Equations used to solve those variables: Equation 644 (size: 1): weaDat.horInfRadSel.uCon = weaDat.horInfRadSel.y Equation 1378 (size: 1): division.y = weaDat.HInfHor_in