Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSysPro_PowerSysPro.Examples.OneSourceOneLoadwithSensors.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1/package.mo", uses=false) Using package PowerSysPro with version 2.3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: translateModel(PowerSysPro.Examples.OneSourceOneLoadwithSensors,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSysPro_PowerSysPro.Examples.OneSourceOneLoadwithSensors") translateModel(PowerSysPro.Examples.OneSourceOneLoadwithSensors,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSysPro_PowerSysPro.Examples.OneSourceOneLoadwithSensors") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001237/0.001237, allocations: 189.9 kB / 16.74 MB, free: 6.762 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.387/1.387, allocations: 222.9 MB / 240.4 MB, free: 4.699 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001276/0.001277, allocations: 103.7 kB / 290.6 MB, free: 2.496 MB / 238.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSysPro 2.3.1/package.mo): time 0.05142/0.05142, allocations: 8.092 MB / 348.9 MB, free: 5.348 MB / 238.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 2.799e-05/2.801e-05, allocations: 2.281 kB / 411.1 MB, free: 43.79 MB / 286.1 MB Notification: Performance of NFInst.instantiate(PowerSysPro.Examples.OneSourceOneLoadwithSensors): time 0.003097/0.003141, allocations: 1.776 MB / 412.9 MB, free: 42.95 MB / 286.1 MB Notification: Performance of NFInst.instExpressions: time 0.00181/0.004967, allocations: 1.328 MB / 414.2 MB, free: 42.05 MB / 286.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0001027/0.005084, allocations: 6.562 kB / 414.2 MB, free: 42.05 MB / 286.1 MB Notification: Performance of NFTyping.typeComponents: time 0.000349/0.005457, allocations: 85 kB / 414.3 MB, free: 42.03 MB / 286.1 MB Notification: Performance of NFTyping.typeBindings: time 0.0002722/0.005738, allocations: 84.05 kB / 414.4 MB, free: 42 MB / 286.1 MB Notification: Performance of NFTyping.typeClassSections: time 0.0008392/0.006586, allocations: 424.4 kB / 414.8 MB, free: 41.8 MB / 286.1 MB Notification: Performance of NFFlatten.flatten: time 0.0002433/0.006838, allocations: 219.4 kB / 415 MB, free: 41.74 MB / 286.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.0002323/0.007076, allocations: 116.3 kB / 415.1 MB, free: 41.7 MB / 286.1 MB Notification: Performance of NFEvalConstants.evaluate: time 0.0001077/0.007193, allocations: 97.52 kB / 415.2 MB, free: 41.65 MB / 286.1 MB Notification: Performance of NFSimplifyModel.simplify: time 0.0002342/0.007433, allocations: 151.9 kB / 415.4 MB, free: 41.58 MB / 286.1 MB Notification: Performance of NFPackage.collectConstants: time 4.878e-05/0.007489, allocations: 20.44 kB / 415.4 MB, free: 41.58 MB / 286.1 MB Notification: Performance of NFFlatten.collectFunctions: time 0.0002783/0.007773, allocations: 130.4 kB / 415.5 MB, free: 41.54 MB / 286.1 MB Notification: Performance of combineBinaries: time 0.000354/0.008134, allocations: 440.6 kB / 416 MB, free: 41.26 MB / 286.1 MB Notification: Performance of replaceArrayConstructors: time 0.0001529/0.008295, allocations: 280 kB / 416.2 MB, free: 41.07 MB / 286.1 MB Notification: Performance of NFVerifyModel.verify: time 5.321e-05/0.008354, allocations: 34.5 kB / 416.3 MB, free: 41.06 MB / 286.1 MB Notification: Performance of FrontEnd: time 2.996e-05/0.008391, allocations: 4.469 kB / 416.3 MB, free: 41.06 MB / 286.1 MB Notification: Performance of Bindings: time 0.00125/0.009648, allocations: 1.444 MB / 417.7 MB, free: 40.04 MB / 286.1 MB Notification: Performance of simplify1: time 4.319e-05/0.0097, allocations: 44.81 kB / 417.8 MB, free: 40.02 MB / 286.1 MB Notification: Performance of Alias: time 0.000915/0.01062, allocations: 0.8018 MB / 418.6 MB, free: 39.45 MB / 286.1 MB Notification: Performance of simplify2: time 3.135e-05/0.01067, allocations: 28.22 kB / 418.6 MB, free: 39.43 MB / 286.1 MB Notification: Performance of Events: time 0.0001302/0.0108, allocations: 80.67 kB / 418.7 MB, free: 39.39 MB / 286.1 MB Notification: Performance of DetectStates: time 0.0001584/0.01097, allocations: 146.1 kB / 418.8 MB, free: 39.3 MB / 286.1 MB Notification: Performance of Partitioning: time 0.0003639/0.01134, allocations: 341.5 kB / 419.1 MB, free: 39.02 MB / 286.1 MB Error: Internal error NBResolveSingularities.noIndexReduction failed because following variables could not be solved: [ALGB] (1) flow Real amp.terminalB.i.im, [ALGB] (1) flow Real volt.terminal.i.re, [ALGB] (1) flow Real amp.terminalA.i.im, [ALGB] (1) flow Real amp.terminalB.i.re, [ALGB] (1) flow Real volt.terminal.i.im, [ALGB] (1) flow Real src.terminal.i.re Furthermore following equations are unmatched: [RECD] (2) volt.terminal.i = Complex(0.0, 0.0) ($RES_SIM_12), [RECD] (2) PowerSysPro.Types.myComplexCurrent.'+'(amp.terminalA.i, amp.terminalB.i) = Complex(0.0, 0.0) ($RES_SIM_14)