Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr PowerGrids_dev_PowerGrids.Examples.IEEE14bus.IEEE14busStaticNetworkEPF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/package.mo", uses=false) Using package PowerGrids with version 2.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(PowerGrids.Examples.IEEE14bus.IEEE14busStaticNetworkEPF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_dev_PowerGrids.Examples.IEEE14bus.IEEE14busStaticNetworkEPF") translateModel(PowerGrids.Examples.IEEE14bus.IEEE14busStaticNetworkEPF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_dev_PowerGrids.Examples.IEEE14bus.IEEE14busStaticNetworkEPF") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001765/0.001765, allocations: 109.3 kB / 16.42 MB, free: 6.52 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001727/0.001727, allocations: 188.2 kB / 17.35 MB, free: 5.75 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.45/1.45, allocations: 222.9 MB / 241 MB, free: 15.16 MB / 206.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/package.mo): time 0.07401/0.07401, allocations: 16.79 MB / 308 MB, free: 14.41 MB / 254.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 4.78e-05/4.781e-05, allocations: 5.094 kB / 427.3 MB, free: 10.56 MB / 302.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus1.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus1.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus2.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus2.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus3.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus3.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus4.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus4.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus5.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus5.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus6.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus6.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus7.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus7.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus8.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus8.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus9.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus9.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus10.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus10.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus11.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus11.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus12.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus12.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus13.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus13.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter bus14.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter bus14.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter busGEN1.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter busGEN1.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter busGEN2.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter busGEN2.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter busGEN3.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter busGEN3.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter busGEN8.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter busGEN8.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L1to2.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L1to2.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L1to5.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L1to5.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L2to3.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L2to3.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L2to4.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L2to4.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L2to5.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L2to5.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L3to4.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L3to4.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L4to5.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L4to5.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L6to11.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L6to11.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L6to12.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L6to12.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L6to13.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L6to13.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L7to8.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L7to8.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L7to9.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L7to9.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L9to10.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L9to10.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L9to14.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L9to14.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L10to11.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L10to11.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L12to13.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L12to13.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter L13to14.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter L13to14.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load2.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load2.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load3.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load3.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load4.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load4.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load5.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load5.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load6.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load6.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load9.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load9.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load10.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load10.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load11.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load11.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load12.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load12.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load13.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load13.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Load14.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Load14.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter Cbank9.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter Cbank9.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter T4to7.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter T4to7.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter T4to9.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter T4to9.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter T5to6.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter T5to6.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter Tgen1.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter Tgen1.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter Tgen2.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter Tgen2.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter Tgen3.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter Tgen3.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:4:3-5:21:writable] Warning: Parameter Tgen8.componentPF.UNomA has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/TwoPortACVI.mo:8:3-9:21:writable] Warning: Parameter Tgen8.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN1.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN1.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN1.GEN.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN1.GEN.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN2.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN2.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN2.GEN.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN2.GEN.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN3.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN3.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN3.GEN.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN3.GEN.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN6.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN6.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN6.GEN.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN6.GEN.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN8.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN8.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:4:3-5:21:writable] Warning: Parameter GEN8.GEN.componentPF.UNom has no value, and is fixed during initialization (fixed=true), using available start value (start=400e3) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 2.0.0-develop/Electrical/BaseClasses/OnePortACVI.mo:6:3-7:21:writable] Warning: Parameter GEN8.GEN.componentPF.SNom has no value, and is fixed during initialization (fixed=true), using available start value (start=100e6) as default value. Notification: Performance of NFInst.instantiate(PowerGrids.Examples.IEEE14bus.IEEE14busStaticNetworkEPF): time 1.994/1.994, allocations: 0.511 GB / 0.9283 GB, free: 19.34 MB / 0.5762 GB Notification: Performance of NFInst.instExpressions: time 0.2602/2.254, allocations: 101.9 MB / 1.028 GB, free: 13.16 MB / 0.5919 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.1075/2.362, allocations: 0.8941 MB / 1.029 GB, free: 12.91 MB / 0.5919 GB Notification: Performance of NFTyping.typeComponents: time 0.07565/2.437, allocations: 14.47 MB / 1.043 GB, free: 2.195 MB / 0.5919 GB Notification: Performance of NFTyping.typeBindings: time 0.1945/2.632, allocations: 42.93 MB / 1.085 GB, free: 2.594 MB / 0.6231 GB Notification: Performance of NFTyping.typeClassSections: time 0.06511/2.697, allocations: 15.99 MB / 1.1 GB, free: 5.23 MB / 0.6387 GB Notification: Performance of NFFlatten.flatten: time 1.235/3.932, allocations: 115.5 MB / 1.213 GB, free: 16.55 MB / 0.7013 GB Notification: Performance of NFFlatten.resolveConnections: time 0.05412/3.986, allocations: 15.5 MB / 1.228 GB, free: 30.34 MB / 0.7169 GB Notification: Performance of NFEvalConstants.evaluate: time 0.09695/4.083, allocations: 34.99 MB / 1.262 GB, free: 26.01 MB / 0.7169 GB Notification: Performance of NFSimplifyModel.simplify: time 0.09359/4.177, allocations: 40.43 MB / 1.302 GB, free: 19.34 MB / 0.7169 GB Notification: Performance of NFPackage.collectConstants: time 0.02832/4.205, allocations: 3.648 MB / 1.306 GB, free: 19.09 MB / 0.7169 GB Notification: Performance of NFFlatten.collectFunctions: time 0.075/4.28, allocations: 8.747 MB / 1.314 GB, free: 10.9 MB / 0.7169 GB Notification: Performance of combineBinaries: time 0.2196/4.5, allocations: 112 MB / 1.423 GB, free: 2.59 MB / 0.795 GB Notification: Performance of replaceArrayConstructors: time 1.325/5.824, allocations: 67.95 MB / 1.49 GB, free: 59.31 MB / 0.8108 GB Notification: Performance of NFVerifyModel.verify: time 0.05857/5.883, allocations: 8.924 MB / 1.498 GB, free: 59.31 MB / 0.8108 GB Notification: Performance of FrontEnd: time 0.02349/5.907, allocations: 1.45 MB / 1.5 GB, free: 59.31 MB / 0.8108 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 9472 (7048) * Number of variables: 9472 (9472) Notification: Performance of Bindings: time 1.471/7.378, allocations: 350.7 MB / 1.842 GB, free: 73.21 MB / 0.8733 GB Notification: Performance of FunctionAlias: time 0.09535/7.473, allocations: 46.5 MB / 1.888 GB, free: 62.19 MB / 0.8733 GB Notification: Performance of Early Inline: time 1.344/8.818, allocations: 194.2 MB / 2.077 GB, free: 75.09 MB / 0.9358 GB Notification: Performance of simplify1: time 0.03163/8.849, allocations: 11.17 MB / 2.088 GB, free: 75.09 MB / 0.9358 GB Notification: Performance of Alias: time 0.349/9.198, allocations: 177 MB / 2.261 GB, free: 4.227 MB / 0.9358 GB Notification: Performance of simplify2: time 0.02309/9.222, allocations: 9.931 MB / 2.271 GB, free: 12.95 MB / 0.9514 GB Notification: Performance of Detect States: time 0.09849/9.32, allocations: 47.73 MB / 2.318 GB, free: 14.89 MB / 0.9983 GB Notification: Performance of Events: time 0.04264/9.363, allocations: 16.81 MB / 2.334 GB, free: 14.44 MB / 1.014 GB Notification: Performance of DAE-Mode: time 2.926e-05/9.363, allocations: 4 kB / 2.334 GB, free: 14.43 MB / 1.014 GB Notification: Performance of Partitioning: time 0.939/10.3, allocations: 57.18 MB / 2.39 GB, free: 162 MB / 1.03 GB Notification: Performance of Causalize: time 0.4286/10.73, allocations: 228.7 MB / 2.613 GB, free: 44.53 MB / 1.03 GB Notification: Performance of After Index Reduction Inline: time 0.9884/11.72, allocations: 103 MB / 2.714 GB, free: 113.1 MB / 1.03 GB Notification: Performance of Inline: time 0.6921/12.41, allocations: 272.1 MB / 2.979 GB, free: 12.55 MB / 1.045 GB Notification: Performance of Partitioning: time 0.04222/12.45, allocations: 13.69 MB / 2.993 GB, free: 4.457 MB / 1.045 GB Notification: Performance of Cleanup: time 0.06451/12.52, allocations: 23.46 MB / 3.016 GB, free: 1.473 MB / 1.061 GB Notification: Performance of Causalize: time 7.495/20.01, allocations: 1.286 GB / 4.302 GB, free: 77.46 MB / 1.248 GB Error: Internal error NBTearing.minimal failed. (2|2) Discrete Variables ************************** [PRMT] (1) final parameter Real GEN8.GEN.rQ1Pu (fixed = false, start = 0.01, min = 1e-5) [PRMT] (1) final parameter Real GEN8.GEN.LQ1Pu (fixed = false, start = 0.5, min = 0.001) (0|0) Discrete Equations ************************** Error: Internal error NBInitialization.main failed to apply modules!